OSHA SearchOSHA records by employer

Las Vegas Drywall & Stucco: OSHA inspections and violations

Las Vegas, Nevada · All Other Specialty Trade Contractors · NAICS 238990

1inspections
5citation items
$1,777current penalties
Aug 30, 2017last inspection

OSHA has inspected Las Vegas Drywall & Stucco once in Nevada.

The inspection began on Aug 30, 2017 on a referral, in Las Vegas.

That inspection ended with 5 citation items: 3 serious and 2 other-than-serious.

Penalties were first proposed at $2,538 and now stand at $1,777, 30% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 4 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Las Vegas Drywall & Stucco averages $1,777 (1 cited inspection).

Las Vegas Drywall & Stucco: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Nevada · latest 90 days of OSHA records

114employers cited

Get notified the morning OSHA posts each new citation in Nevada: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Nevada

Checking a subcontractor, a client or your own company? Watch Las Vegas Drywall & Stucco and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342626918 OPENED AUG 30, 2017Closed

Referral · Partial · Safety · 3 employees at the site · Closed Jan 2, 2018

3013 South Highland Drive, Las Vegas, NV 89109 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$810$567Oct 6, 2017Final
Citation 1, item 2
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$918$643Oct 6, 2017Final
Citation 1, item 3
29 CFR 1926.454(a) · Scaffold training
Serious$810$567Oct 6, 2017Final
Citation 2, item 1
29 CFR 1926.451(b)(7) · Scaffolds, general requirements
Other-than-serious$0$0Oct 6, 2017Final
Citation 2, item 2
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Other-than-serious$0$0Oct 6, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(7)

(7) On scaffolds where platforms are overlapped to create a long platform, the overlap shall occur only over supports, and shall not be less than 12 inches (30 cm) unless the platforms are nailed together or otherwise restrained to prevent movement.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.

29 CFR 1926.454 · Scaffold training