OSHA SearchOSHA records by employer

Las Vegas Electric, Inc.: OSHA inspections and violations

Las Vegas, Nevada · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

10inspections
19citation items
$6,685current penalties
Jun 15, 2020last inspection

Las Vegas Electric, Inc. has 10 OSHA inspections on record in Nevada, the first in 1982.

OSHA's last visit started on Jun 15, 2020 on a referral, in Las Vegas.

Across those inspections OSHA issued 19 citation items: 6 serious and 13 other-than-serious.

OSHA proposed $15,461 in penalties. After settlements and reviews the total is $6,685, down 57%.

Most often, OSHA cited 6180.5420, (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Las Vegas Electric, Inc. averages $1,000 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

Las Vegas Electric, Inc. also files yearly injury logs with OSHA, summarized below.

Las Vegas Electric, Inc.: OSHA citation items per year, 1982 to 2020
Citation items per year, by inspection date.

Nevada · latest 90 days of OSHA records

114employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Nevada: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Nevada

Checking a subcontractor, a client or your own company? Watch Las Vegas Electric, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344788575 OPENED JUN 15, 2020Closed

Referral · Partial · Health · 55 employees at the site · Closed Jul 7, 2020

Intersection Of North Hualapai Way And West Farm Road, Las Vegas, NV 89166 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344731732 OPENED APR 17, 2020Closed

Unprogrammed related · Partial · Health · 55 employees at the site · Closed Jun 29, 2020

South Buffalo Drive And Peace Way, Las Vegas, NV 89147 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR NEVADA REVISED STATUTES 618.375(2
Other-than-serious$8,501$1,000Jun 1, 2020Final

Inspection 316838150 OPENED DEC 5, 2012Closed

Referral · Partial · Safety · 6 employees at the site · Closed Mar 8, 2013

Sw Corner Of Valley View Blvd. & Sirius Ave., Las Vegas, NV 89102 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$2,100$1,575Feb 4, 2013Closed
Citation 1, item 3
29 CFR 1926.652(a)(1) · Trench protection
Serious$1,785$1,785Feb 4, 2013Closed
Citation 2, item 1
29 CFR 1926.651(j)(2) · Excavations
Other-than-serious$0$0Feb 1, 2013Closed

Inspection 310429030 OPENED JAN 26, 2007Closed

Referral · Partial · Safety · 36 employees at the site · Closed Mar 21, 2007

Sunset/valley View, Las Vegas, NV 89102 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.100(a) · Hard hats in construction
Serious$700$700Feb 26, 2007Closed
Citation 1, item 1b
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$0$0Feb 26, 2007Closed

Inspection 308697036 OPENED JUN 1, 2005Closed

Referral · Partial · Safety · 30 employees at the site · Closed Jun 28, 2005

Green Valley/wingbrook Ave, Henderson, NV 89074 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$875$875Jun 21, 2005Closed
Citation 2, item 1 Other-than-serious$0$0Jun 14, 2005Closed

Inspection 303963979 OPENED NOV 15, 2000Closed

Planned · Complete · Safety · 6 employees at the site · Closed Dec 14, 2000

7610 West Cimarron Road, Las Vegas, NV 89148 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 302526421 OPENED MAR 3, 1999Closed

Planned · Complete · Safety · 4 employees at the site · Closed Jun 3, 1999

15 North Gibson Road, (i-215 Beltway), Henderson, NV 89015 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.59(g)(8) · Hazard communication
Other-than-serious$0$0Apr 19, 1999Closed
Citation 2, item 1 Other-than-serious$0$0Mar 24, 1999Closed
Citation 2, item 2 Other-than-serious$0$0Mar 24, 1999Closed
Citation 2, item 3 Other-than-serious$0$0Mar 24, 1999Closed
Citation 2, item 4 Other-than-serious$0$0Mar 24, 1999Closed
Citation 2, item 5 Other-than-serious$0$0Mar 24, 1999Closed
Citation 2, item 6 Other-than-serious$0$0Mar 24, 1999Closed
Citation 2, item 7 Other-than-serious$0$0Mar 24, 1999Closed
Citation 2, item 8 Other-than-serious$0$0Mar 24, 1999Closed
Citation 2, item 9 Other-than-serious$0$0Mar 24, 1999Closed

Inspection 114571458 OPENED JUN 30, 1992Closed

Accident · Partial · Safety · 8 employees at the site · Closed Sep 18, 1992

41 North Mojave Road, Las Vegas, NV 89110 · OSHA's record · Phone and website on Google Maps

Incident on Jun 28, 1992 (fatal): Electric shock - direct contact with energized parts

AN ELECTRICIAN WAS PULLING AN ELECTRICAL SERVICE INTO A 2000-AMPERE, 480-VOLT MA IN SERVICE PANELBOARD. THE EMPLOYER SCHEDULED THE WORK ON A SUNDAY BECAUSE THE F ACILITY WAS A FOOD STORAGE AND PROCESSING PLANT, WHICH WOULD BE LEAST AFFECTED B Y A POWER OUTAGE ON A NON-WORKDAY. THE COMPANY'S SENIOR OFFICER, WHO WAS ASSISTI NG AS WELL AS SUPERVISING, ATTEMPTED TO DEENERGIZE THE SYSTEM BY OPENING THE MAI N DISCONNECT. THIS ACTION, HOWEVER, ONLY DEENERGIZED THE LOAD SIDE OF THE CIRCUI T, AND THE SERVICE ENTRANCE CONDUCTORS WERE STILL ENERGIZED. THE SUPERVISOR INST RUCTED THE CREW TO TEST THE CIRCUITS BEFORE BEGINNING WORK. ANOTHER EMPLOYEE OPE NED A SUB-PANEL, TESTED IT, AND FOUND IT TO BE DEENERGIZED. HE RELAYED THIS INFO RMATION TO THE OTHER CREW MEMBERS. SOON AFTER THIS, THE SUPERVISOR AND ANOTHER E MPLOYEE NOTICED THE ELECTRICIAN SLUMPED OVER AT HIS WORK AREA (THE MAIN PANELBOA RD). THE ELECTRICIAN WAS BLEEDING FROM HIS HEAD AND WAS NOT BREATHING. HE DIED O F ELECTROCUTION A SHORT TIME LATER. AFTER THE ACCIDENT, A CHECK FOUND AN ENERGIZ ED LINE WITHIN THE ELECTRICIAN'S WORK AREA. IT WAS THE 480-VOLT (277-VOLT-TO-GRO UND) SERVICE ENTRANCE CONDUCTORS FOR THE MAIN CIRCUIT BREAKER, AND IT ORIGINATED AT THE ELECTRIC UTILITY'S TRANSFORMER. THE TERMINAL LUGS AND BUSES TO WHICH THE SE CONDUCTORS WERE CONNECTED WERE ALSO ENERGIZED.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.416(a)(3) · Electrical safety in construction
Serious$1,500$750Aug 14, 1992Closed
2 older inspections

Inspection 218241370 OPENED MAY 2, 1983Closed

Planned · Complete · Safety · 2 employees at the site · Closed May 3, 1983

527 S Fourth St, Las Vegas, NV 89101 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 218242691 OPENED JUN 1, 1982Closed

Planned · Complete · Safety · 3 employees at the site · Closed Mar 10, 1984

888 South Rancho Drive, Las Vegas, NV 89106 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Las Vegas site logged 5 recordable injuries or illnesses among about 68 workers: 7.0 per 100 full-time workers, against a median of 1.8 for its industry. Those cases cost 22 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Las Vegas Electric Inc
Las Vegas · 2025
68 537.01.8
Las Vegas Electric Inc.
Las Vegas · 2023
75 526.71.8
Las Vegas Electric
Las Vegas · 2022
69 111.51.8
Las Vegas Electric, Inc.
Las Vegas · 2017
73 428.01.8

Included with any plan: 4 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(a)(3)

(3) Before work is begun the employer shall ascertain by inquiry or direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, is so located that the performance of the work may bring any person, tool, or machine into physical or electrical contact with the electric power circuit. The employer shall post and maintain proper warning signs where such a circuit exists. The employer shall advise employees of the location of such lines, the hazards involved, and the protective measures to be taken.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.59 · Hazard communication

29 CFR 1926.651 · Excavations

29 CFR 1926.652 · Trench protection

29 CFR 6180.3450

29 CFR 6180.3750

29 CFR 6180.5400

29 CFR 6180.5420

29 CFR 6180.5560

29 CFR 6180.5650

Other electrical contractors and other wiring installation contractors employers in Nevada

Alert subscribers get notified of each newly cited employer in Nevada the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.