OSHA SearchOSHA records by employer

Laundry Wave Inc: OSHA inspections and violations

Clifton, New Jersey · Commercial and Institutional Building Construction · NAICS 236220

1inspections
3citation items
$2,993current penalties
Oct 16, 2017last inspection

Laundry Wave Inc has one OSHA inspection on record in New Jersey.

OSHA opened it on Oct 16, 2017 after a complaint, in Clifton.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $4,989 in penalties. After settlements and reviews the total is $2,993, down 40%.

Most often, OSHA cited 1926.403, electrical equipment on job sites (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Laundry Wave Inc averages $2,993 over 1 cited inspection in that time.

Laundry Wave Inc: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

270employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch Laundry Wave Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342707544 OPENED OCT 16, 2017Closed

Complaint · Partial · Safety · 3 employees at the site · Closed Jun 5, 2018

500 Lexington Ave., Clifton, NJ 07011 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$2,217$1,330Apr 6, 2018Final
Citation 1, item 1b
29 CFR 1926.405(a)(2)(ii)(b) · Job-site wiring
Serious$0$0Apr 6, 2018Final
Citation 1, item 2
29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites
Serious$2,772$1,663Apr 6, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(2)

(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.

29 CFR 1926.403(i)(2)(i)

(2) Guarding of live parts. (i) Except as required or permitted elsewhere in this subpart, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by cabinets or other forms of enclosures, or by any of the following means:

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(a)(2)(ii)(b)

(B) Branch circuits shall originate in a power outlet or panelboard. Conductors shall be run as multiconductor cord or cable assemblies or open conductors, or shall be run in raceways. All conductors shall be protected by overcurrent devices at their ampacity. Runs of open conductors shall be located where the conductors will not be subject to physical damage, and the conductors shall be fastened at intervals not exceeding 10 feet (3.05 m). No branch-circuit conductors shall be laid on the floor. Each branch circuit that supplies receptacles or fixed equipment shall contain a separate equipment grounding conductor if the branch circuit is run as open conductors.

Other commercial and institutional building construction employers in New Jersey

Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.