OSHA SearchOSHA records by employer

Laurel Valley Graphics, Inc.: OSHA inspections and violations

Latrobe, Pennsylvania · Commercial Screen Printing · NAICS 323113

1inspections
5citation items
$3,000current penalties
Oct 24, 2016last inspection

OSHA has inspected Laurel Valley Graphics, Inc. once in Pennsylvania.

The inspection began on Oct 24, 2016 as a planned inspection, in Latrobe.

That inspection ended with 5 citation items: 4 serious and 1 other-than-serious.

Penalties were first proposed at $4,988 and now stand at $3,000, 40% lower after settlements or reviews.

Lockout/tagout comes up most often in these citations: 4 items under 1910.147.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Laurel Valley Graphics, Inc. averages $3,000 (1 cited inspection).

Laurel Valley Graphics, Inc.: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

287employers cited

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Laurel Valley Graphics, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341858991 OPENED OCT 24, 2016Closed

Planned · Partial · Safety · 17 employees at the site · Closed Jan 23, 2017

1511 Monsetary Drive, Latrobe, PA 15650 · Commercial Screen Printing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$2,138$1,000Nov 30, 2016Final
Citation 1, item 1b
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$0$0Nov 30, 2016Final
Citation 1, item 1c Serious$0$0Nov 30, 2016Final
Citation 1, item 2
29 CFR 1910.147(d)(4)(i) · Lockout/tagout
Serious$2,850$2,000Nov 30, 2016Final
Citation 2, item 1
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Nov 30, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

29 CFR 1910.147(c)(7)(iii)(a)

(A) Retraining shall be provided for all authorized and affected employees whenever there is a change in their job assignments, a change in machines, equipment or processes that present a new hazard, or when there is a change in the energy control procedures.

29 CFR 1910.303 · Electrical equipment, general requirements

Other commercial screen printing employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.