OSHA SearchOSHA records by employer

Leancor: OSHA inspections and violations

Cedar Rapids, Iowa · General Warehousing and Storage · NAICS 493110

1inspections
3citation items
$2,975current penalties
Jun 28, 2017last inspection

Leancor has one OSHA inspection on record in Iowa.

OSHA opened it on Jun 28, 2017 after a complaint, in Cedar Rapids.

From that inspection OSHA issued 3 citation items: 2 serious and 1 other-than-serious.

OSHA proposed $5,950 in penalties. After settlements and reviews the total is $2,975, down 50%.

For context, across all transportation and warehousing employers the median penalty per cited inspection since 2015 is $3,555. Leancor averages $2,975 over 1 cited inspection in that time.

Leancor: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Want to know if OSHA cites Leancor again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342446333 OPENED JUN 28, 2017Closed

Complaint · Partial · Safety · 65 employees at the site · Closed Sep 5, 2017

5000 20th Ave Sw, Cedar Rapids, IA 52404 · General Warehousing and Storage · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements
Serious$1,750$875Aug 9, 2017Final
Citation 1, item 2
29 CFR 1910.305(d)(2) · Electrical wiring methods
Serious$3,500$1,750Aug 9, 2017Final
Citation 2, item 1
29 CFR 1910.22(a)(3) · Walking-working surfaces
Other-than-serious$700$350Aug 9, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.22 · Walking-working surfaces

29 CFR 1910.22(a)(3)

(3) Walking-working surfaces are maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(7)(iv)

(iv) There shall be no damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(d)(2)

(2) Panelboard enclosures. Panelboards shall be mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons.

Other general warehousing and storage employers in Iowa

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.