OSHA SearchOSHA records by employer

Lec Cabinets LLC: OSHA inspections and violations

Tooele, Utah · Wood Kitchen Cabinet and Countertop Manufacturing · NAICS 337110

2inspections
5citation items
$750current penalties
Mar 4, 2025last inspection

OSHA has inspected Lec Cabinets LLC 2 times in Utah since 2016.

The latest one began on Mar 4, 2025 as a planned inspection, in Tooele.

Those inspections ended with 5 citation items: 3 serious and 2 other-than-serious.

Penalties were first proposed at $1,500 and now stand at $750, 50% lower after settlements or reviews.

Lockout/tagout comes up most often in these citations: 4 items under 1910.147.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Lec Cabinets LLC averages $375 (2 cited inspections).

Lec Cabinets LLC: OSHA citation items per year, 2016 to 2025
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

67employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch Lec Cabinets LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348073156 OPENED MAR 4, 2025Closed

Planned · Partial · Safety · 20 employees at the site · Closed Mar 14, 2025

310 E 2000 N, Tooele, UT 84074 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR UAC R614-1-5.D.5
Other-than-serious$0$0Mar 12, 2025Final
Citation 1, item 2
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$0$0Mar 12, 2025Final

Inspection 341636744 OPENED JUL 21, 2016Closed

Planned · Partial · Safety · 15 employees at the site · Closed Oct 19, 2016

10 S Garnett St. Ste 10, Tooele, UT 84074 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$1,500$750Aug 18, 2016Final
Citation 1, item 1b
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$0$0Aug 18, 2016Final
Citation 1, item 1c
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Aug 18, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

Other wood kitchen cabinet and countertop manufacturing employers in Utah

Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.