Lee Electrical Construction LLC: OSHA inspections and violations

Chesapeake, Virginia · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

3inspections
3citation items
$18,270current penalties
Oct 5, 2026last inspection

OSHA has inspected Lee Electrical Construction LLC 3 times in Virginia since 2010.

The latest one began on Oct 5, 2026 on a referral, in King And Queen Court House; the case is still open.

Those inspections ended with 3 citation items: 3 other-than-serious.

Penalties were first proposed at $20,570 and now stand at $18,270, 11% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Lee Electrical Construction LLC averages $14,270 (1 cited inspection).

Lee Electrical Construction LLC: OSHA citation items per year, 2010 to 2026
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

253employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Lee Electrical Construction LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 349199562 OPENED OCT 5, 2026Open

Referral · Partial · Safety · 4 employees at the site · Open

3500 Liberty Hall Road, King And Queen Court House, VA 23085 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection so far.

Inspection 346710130 OPENED MAY 18, 2023Closed

Complaint · Partial · Safety · 2 employees at the site · Closed Sep 9, 2024

6306 Howerton Road, Dunnsville, VA 22454 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.959(d)(1) · Mechanical equipment
Other-than-serious$14,270$14,270Oct 12, 2023Final
Citation 2, item 1
29 CFR 1926.50(c) · Medical services and first aid
Other-than-serious$0$0Oct 12, 2023Final

Inspection 314909961 OPENED SEP 9, 2010Closed

Planned · Partial · Safety · 4 employees at the site · Closed Nov 10, 2010

300 Priority Lane, Chesapeake, VA 23324 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.269(p)(4)(ii) · Electric power generation, transmission, and distribution
Other-than-serious$6,300$4,000Oct 5, 2010Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.269 · Electric power generation, transmission, and distribution

29 CFR 1910.269(p)(4)(ii)

(ii) A designated employee other than the equipment operator shall observe the approach distance to exposed lines and equipment and provide timely warnings before the minimum approach distance required by paragraph (p)(4)(i) of this section is reached, unless the employer can demonstrate that the operator can accurately determine that the minimum approach distance is being maintained.

29 CFR 1926.50 · Medical services and first aid

29 CFR 1926.50(c)

(c) In the absence of an infirmary, clinic, hospital, or physician, that is reasonably accessible in terms of time and distance to the worksite, which is available for the treatment of injured employees, a person who has a valid certificate in first-aid training from the U.S. Bureau of Mines, the American Red Cross, or equivalent training that can be verified by documentary evidence, shall be available at the worksite to render first aid.

29 CFR 1926.959 · Mechanical equipment

29 CFR 1926.959(d)(1)

(d) Operations near energized lines or equipment—(1) Minimum approach distance. Mechanical equipment shall be operated so that the minimum approach distances, established by the employer under § 1926.960(c)(1)(i), are maintained from exposed energized lines and equipment. However, the insulated portion of an aerial lift operated by a qualified employee in the lift is exempt from this requirement if the applicable minimum approach distance is maintained between the uninsulated portions of the aerial lift and exposed objects having a different electrical potential.

Other electrical contractors and other wiring installation contractors employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.