OSHA SearchOSHA records by employer

Lehigh Valley Underground: OSHA inspections and violations

Easton, Pennsylvania · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

4inspections
6citation items
$28,671current penalties
Jan 21, 2021last inspection

Lehigh Valley Underground has 4 OSHA inspections on record in Pennsylvania, the first in 2019.

OSHA's last visit started on Jan 21, 2021 after a complaint, in Allentown.

Across those inspections OSHA issued 6 citation items: 6 serious.

OSHA proposed $28,671 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.960, working on or near exposed energized parts (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Lehigh Valley Underground averages $28,671 over 1 cited inspection in that time.

Lehigh Valley Underground: OSHA citation items per year, 2019 to 2021
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

285employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Lehigh Valley Underground and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345110191 OPENED JAN 21, 2021Closed

Complaint · Partial · Safety · 7 employees at the site · Closed Jun 22, 2021

Grange Rd. West Of Mill Creek Rd., Allentown, PA 18106 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344933015 OPENED SEP 17, 2020Closed

Complaint · Partial · Safety · 35 employees at the site · Closed Mar 11, 2025

287 Stonehaven Dr., Red Hill, PA 18073 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.951(b)(1) · Medical services and first aid
Serious$9,557$9,557Mar 15, 2021Final
Citation 1, item 2a
29 CFR 1926.952(a)(2) · Job briefing
Serious$9,557$9,557Mar 15, 2021Final
Citation 1, item 2b
29 CFR 1926.960(g)(1) · Working on or near exposed energized parts
Serious$0$0Mar 15, 2021Final
Citation 1, item 2c
29 CFR 1926.960(g)(5) · Working on or near exposed energized parts
Serious$0$0Mar 15, 2021Final
Citation 1, item 3a
29 CFR 1926.960(b)(1)(ii) · Working on or near exposed energized parts
Serious$9,557$9,557Mar 15, 2021Final
Citation 1, item 3b
29 CFR 1926.960(c)(1)(iii) · Working on or near exposed energized parts
Serious$0$0Mar 15, 2021Final

Inspection 344911672 OPENED SEP 8, 2020Closed

Complaint · No inspection · Safety · 30 employees at the site · Closed Nov 6, 2020

240 Stable Rd, Lehighton, PA 18235 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344127105 OPENED JUN 27, 2019Closed

Complaint · No inspection · Health · 15 employees at the site · Closed Jun 27, 2019

3301 Northwood Ave., Easton, PA 18045 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.951 · Medical services and first aid

29 CFR 1926.951(b)(1)

(1) Field work. For field work involving two or more employees at a work location, at least two trained persons shall be available.

29 CFR 1926.952 · Job briefing

29 CFR 1926.952(a)(2)

(2) Briefing by the employee in charge. The employer shall ensure that the employee in charge conducts a job briefing that meets paragraphs (b), (c), and (d) of this section with the employees involved before they start each job.

29 CFR 1926.960 · Working on or near exposed energized parts

29 CFR 1926.960(b)(1)(ii)

(ii) Only qualified employees may work in areas containing unguarded, uninsulated energized lines or parts of equipment operating at 50 volts or more.