Leis by Ron, Inc.: OSHA inspections and violations

Honolulu, Hawaii · Flower, Nursery Stock, and Florists' Supplies Merchant Wholesalers · NAICS 424930

3inspections
8citation items
$1,125current penalties
Oct 9, 2017last inspection

Leis by Ron, Inc. has 3 OSHA inspections on record in Hawaii, the first in 2002.

OSHA's last visit started on Oct 9, 2017 as a planned inspection, in Honolulu.

Across those inspections OSHA issued 8 citation items: 3 serious and 5 other-than-serious.

OSHA proposed $1,125 in penalties and the amount has not been reduced.

Most often, OSHA cited 1910.303, electrical equipment, general requirements (2 items).

For context, across all wholesale employers the median penalty per cited inspection since 2015 is $3,425. Leis by Ron, Inc. averages $0 over 1 cited inspection in that time.

Leis by Ron, Inc.: OSHA citation items per year, 2002 to 2017
Citation items per year, by inspection date.

Hawaii · latest 90 days of OSHA records

63employers cited

Get notified the morning OSHA posts each new citation in Hawaii: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Hawaii

Checking a subcontractor, a client or your own company? Watch Leis by Ron, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342691805 OPENED OCT 9, 2017Closed

Planned · Complete · Health · 12 employees at the site · Closed Nov 8, 2017

851 Mapunapuna St Bay 3, Honolulu, HI 96819 · Flower, Nursery Stock, and Florists' Supplies Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Oct 24, 2017Final

Inspection 313078222 OPENED DEC 3, 2009Closed

Planned · Complete · Health · 7 employees at the site · Closed Mar 29, 2010

851 Mapunapuna St Bay #3, Honolulu, HI 96819 · Flower, Nursery Stock, and Florists' Supplies Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$375$375Feb 19, 2010Closed
Citation 1, item 2
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$375$375Feb 19, 2010Closed
Citation 1, item 3
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Serious$375$375Feb 19, 2010Closed
Citation 2, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Feb 19, 2010Closed
Citation 2, item 2
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Feb 19, 2010Closed
Citation 2, item 3
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Feb 19, 2010Closed

Inspection 305304602 OPENED OCT 9, 2002Closed

Planned · Complete · Safety · 9 employees at the site · Closed Oct 22, 2002

851 Mapunapuna St Bay #3, Honolulu, HI 96819 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Oct 17, 2002Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(e)(3)

(3) The employer shall assure that portable fire extinguishers are subjected to an annual maintenance check. Stored pressure extinguishers do not require an internal examination. The employer shall record the annual maintenance date and retain this record for one year after the last entry or the life of the shell, whichever is less. The record shall be available to the Assistant Secretary upon request.

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(2)

(2) Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.

29 CFR 1910.303(g)(1)

(1) Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods