Inspection 349205518 OPENED OCT 7, 2026Open
9386 Rockingham Drive, Peyton, CO 80831 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
Colorado Springs, Colorado · Water and Sewer Line and Related Structures Construction · NAICS 237110
OSHA has inspected Leo's Sewer & Drain Inc. 5 times in Colorado since 2018.
The latest one began on Oct 7, 2026 after a complaint, in Peyton; the case is still open.
Those inspections ended with 7 citation items: 4 serious and 3 repeat.
Penalties were first proposed at $121,254 and now stand at $96,600, 20% lower after settlements or reviews.
Trench protection comes up most often in these citations: 3 items under 1926.652.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Leo's Sewer & Drain Inc. averages $32,200 (3 cited inspections).
Colorado · latest 90 days of OSHA records
142employers cited
3 of them in the same industry
Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Colorado
Checking a subcontractor, a client or your own company? Watch Leo's Sewer & Drain Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company9386 Rockingham Drive, Peyton, CO 80831 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
2145 Broadmoor Road Circle, Colorado Springs, CO 80906 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Adj. 230 Balmoral Way, Colorado Springs, CO 80906 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.652(a)(1) · Trench protection |
Repeat | $29,687 | $20,000 | Nov 18, 2020 | Final |
4448 White Oak Ct., Colorado Springs, CO 80906 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.652(a)(1) · Trench protection |
Repeat | $74,215 | $70,000 | Jan 24, 2020 | Final |
| Citation 2, item 1 29 CFR 1926.21(b)(2) · Construction safety training |
Repeat | $8,482 | $2,000 | Jan 24, 2020 | Final |
1535 S. 8th St., Colorado Springs, CO 80905 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.651(j)(2) · Excavations |
Serious | $3,696 | $2,200 | Sep 17, 2018 | Final |
| Citation 1, item 1b 29 CFR 1926.652(a)(1) · Trench protection |
Serious | $0 | $0 | Sep 17, 2018 | Final |
| Citation 1, item 2a 29 CFR 1926.651(k)(1) · Excavations |
Serious | $5,174 | $2,400 | Sep 17, 2018 | Final |
| Citation 1, item 2b 29 CFR 1926.21(b)(2) · Construction safety training |
Serious | $0 | $0 | Sep 17, 2018 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.21(b)(2)
(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.
29 CFR 1926.651(j)(2)
(2) Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.
29 CFR 1926.651(k)(1)
(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.