OSHA SearchOSHA records by employer

Leq Construction 03 LLC: OSHA inspections and violations

Nashville, Tennessee · Drywall and Insulation Contractors · NAICS 238310

2inspections
9citation items
$5,600current penalties
Feb 25, 2025last inspection

OSHA has inspected Leq Construction 03 LLC 2 times in Tennessee since 2023.

The latest one began on Feb 25, 2025, in Morristown.

Those inspections ended with 9 citation items: 4 serious and 5 other-than-serious.

Penalties were first proposed at $5,600 and still stand at $5,600.

Scaffolds, general requirements comes up most often in these citations: 5 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Leq Construction 03 LLC averages $2,800 (2 cited inspections).

Leq Construction 03 LLC: OSHA citation items per year, 2023 to 2025
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

342employers cited

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Leq Construction 03 LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348064981 OPENED FEB 25, 2025Closed

Unprogrammed other · Complete · Safety · 4 employees at the site · Closed Oct 2, 2025

4363 Evan Greene Plaza, Morristown, TN 37814 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$4,000$4,000Apr 7, 2025Final
Citation 2, item 1a
29 CFR 1926.451(h)(2)(i) · Scaffolds, general requirements
Other-than-serious$0$0Apr 7, 2025Final
Citation 2, item 1b
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Other-than-serious$0$0Apr 7, 2025Final

Inspection 346873862 OPENED JUL 28, 2023Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Mar 20, 2024

600 Ermac Dr, Nashville, TN 37214 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$500$500Sep 25, 2023Final
Citation 1, item 1b
29 CFR 1926.451(f)(4) · Scaffolds, general requirements
Serious$0$0Sep 25, 2023Final
Citation 1, item 2
29 CFR 1926.452(a)(4) · Rules for each type of scaffold
Serious$700$700Sep 25, 2023Final
Citation 2, item 2a
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Sep 25, 2023Final
Citation 2, item 2b
29 CFR 1910.1200(g)(1) · Hazard communication
Other-than-serious$0$0Sep 25, 2023Final
Citation 2, item 3
29 CFR TDLWD RULE 800-01-04-.23(4)(A)
Other-than-serious$400$400Feb 7, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(g)(1)

(g) Safety data sheets. (1) Chemical manufacturers and importers shall obtain or develop a safety data sheet for each hazardous chemical they produce or import. Employers shall have a safety data sheet in the workplace for each hazardous chemical which they use.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.452 · Rules for each type of scaffold