OSHA SearchOSHA records by employer

Lighting Resources LLC: OSHA inspections and violations

Greenwood, Indiana · Materials Recovery Facilities · NAICS 562920

6inspections
25citation items
$16,735current penalties
Jul 29, 2020last inspection

Lighting Resources LLC has 6 OSHA inspections on record in Indiana, the first in 1996.

OSHA's last visit started on Jul 29, 2020 after a complaint, in Greenwood.

Across those inspections OSHA issued 25 citation items: 19 serious and 6 other-than-serious.

OSHA proposed $30,650 in penalties. After settlements and reviews the total is $16,735, down 45%.

Most often, OSHA cited 1910.95, noise (5 items).

For context, across all staffing, cleaning and waste services employers the median penalty per cited inspection since 2015 is $2,201. Lighting Resources LLC averages $4,640 over 2 cited inspections in that time.

Lighting Resources LLC also files yearly injury logs with OSHA, summarized below.

Lighting Resources LLC: OSHA citation items per year, 1996 to 2020
Citation items per year, by inspection date.

Want to know if OSHA cites Lighting Resources LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344874326 OPENED JUL 29, 2020Closed

Complaint · Partial · Health · 23 employees at the site · Closed May 18, 2022

498 Park 800 Drive, Greenwood, IN 46143 · Materials Recovery Facilities · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$3,200$2,080Mar 23, 2022Final

Inspection 342557824 OPENED AUG 2, 2017Closed

Referral · Partial · Health · 32 employees at the site · Closed Jun 11, 2018

498 Park 800 Drive, Greenwood, IN 46143 · Materials Recovery Facilities · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Serious$3,000$3,000Jan 17, 2018Final
Citation 1, item 3
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Serious$2,100$0Jan 17, 2018Final
Citation 1, item 4
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$2,100$2,100Jan 17, 2018Final
Citation 1, item 5
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$3,000$0Jan 17, 2018Final
Citation 1, item 6
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$2,100$0Jan 17, 2018Final
Citation 1, item 7
29 CFR 1910.305(j)(2)(iv) · Electrical wiring methods
Serious$2,100$2,100Jan 17, 2018Final
Citation 2, item 1
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Other-than-serious$600$0Jan 17, 2018Final

Inspection 316544899 OPENED DEC 18, 2012Closed

Complaint · Partial · Health · 30 employees at the site · Closed Apr 3, 2013

498 Park 800 Drive, Greenwood, IN 46143 · Materials Recovery Facilities · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 314357393 OPENED APR 20, 2010Closed

Referral · Partial · Health · 31 employees at the site · Closed Feb 11, 2011

498 Park 800 Drive, Greenwood, IN 46143 · Other Services to Buildings and Dwellings · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.36(g)(2) · Exit route design
Serious$1,250$1,000Jun 9, 2010Closed
Citation 1, item 2
29 CFR 1910.37(a)(1) · Exit routes
Other-than-serious$1,250$0Jun 9, 2010Closed
Citation 1, item 3a Serious$2,500$2,000Jun 9, 2010Closed
Citation 1, item 3b Serious$0$0Jun 9, 2010Closed
Citation 1, item 3c Serious$0$0Jun 9, 2010Closed
Citation 1, item 3d Serious$0$0Jun 9, 2010Closed
Citation 1, item 3e Serious$0$0Jun 9, 2010Closed
Citation 1, item 4
29 CFR 1910.141(g)(2) · Sanitation
Serious$1,250$1,000Jun 9, 2010Closed
Citation 1, item 5
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,250$1,000Jun 9, 2010Closed
Citation 1, item 6
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Other-than-serious$750$0Jun 9, 2010Closed
Citation 1, item 7a
29 CFR 1910.1000(b)(1) · Air contaminants
Serious$2,500$2,000Jun 9, 2010Closed
Citation 1, item 7b
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0Jun 9, 2010Closed
Citation 1, item 7c
29 CFR 1910.134(d)(1)(i) · Respiratory protection
Serious$0$0Jun 9, 2010Closed
Citation 1, item 8
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$1,000$0Jun 9, 2010Closed
Citation 2, item 1
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$0$0Jun 9, 2010Closed

Inspection 308200674 OPENED MAR 23, 2005Closed

Complaint · Partial · Safety · 20 employees at the site · Closed May 13, 2005

498 Park 800 Drive, Greenwood, IN 46143 · Materials Recovery Facilities · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$700$455Apr 22, 2005Closed

Inspection 125375725 OPENED JUL 2, 1996Closed

Referral · Partial · Health · 10 employees at the site · Closed Sep 27, 1996

498 Park 800 Drive, Greenwood, IN 46143 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 4000402
Other-than-serious$0$0Sep 13, 1996Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2018, the Greenwood site logged 1 recordable injury or illness among about 35 workers: 2.7 per 100 full-time workers, against a median of 1.0 for its industry. Those cases cost 6 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Lighting Resources Greenwood
Greenwood · 2018
35 112.71.0

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.1000(b)(1)

(1) 8-hour time weighted averages. An employee's exposure to any substance listed in Table Z-2, in any 8-hour work shift of a 40-hour work week, shall not exceed the 8-hour time weighted average limit given for that substance in Table Z-2.

29 CFR 1910.1000(e)

(e) To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.141 · Sanitation

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

29 CFR 1910.95 · Noise

Other materials recovery facilities employers in Indiana