OSHA SearchOSHA records by employer

Lincoln Energy Mechanical Services, Inc.: OSHA inspections and violations

Providence, Rhode Island · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

1inspections
3citation items
$3,000current penalties
May 7, 2015last inspection

OSHA has inspected Lincoln Energy Mechanical Services, Inc. once in Rhode Island.

The inspection began on May 7, 2015 on a referral, in Providence.

That inspection ended with 3 citation items: 2 serious and 1 other-than-serious.

Penalties were first proposed at $6,000 and now stand at $3,000, 50% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Lincoln Energy Mechanical Services, Inc. averages $3,000 (1 cited inspection).

Lincoln Energy Mechanical Services, Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Rhode Island · latest 90 days of OSHA records

79employers cited

Get notified the morning OSHA posts each new citation in Rhode Island: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Rhode Island

Checking a subcontractor, a client or your own company? Watch Lincoln Energy Mechanical Services, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340614106 OPENED MAY 7, 2015Closed

Referral · Partial · Safety · 10 employees at the site · Closed Dec 1, 2015

141 Westminster Street, Providence, RI 02903 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(15) · Fall protection in construction
Serious$2,800$1,400Jun 1, 2015Final
Citation 1, item 2
29 CFR 1926.1053(b)(13) · Ladders in construction
Serious$2,800$1,400Jun 1, 2015Final
Citation 2, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Other-than-serious$400$200Jun 1, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(13)

(13) The top or top step of a stepladder shall not be used as a step.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(15)

(15) Walking/working surfaces not otherwise addressed. Except as provided in § 1926.500(a)(2) or in § 1926.501 (b)(1) through (b)(14), each employee on a walking/working surface 6 feet (1.8 m) or more above lower levels shall be protected from falling by a guardrail system, safety net system, or personal fall arrest system.

Other plumbing, heating, and air-conditioning contractors employers in Rhode Island

Alert subscribers get notified of each newly cited employer in Rhode Island the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.