OSHA SearchOSHA records by employer

Lithko Contracting, LLC: OSHA inspections and violations

Norman, Oklahoma · Poured Concrete Foundation and Structure Contractors · NAICS 238110

6inspections
3citation items
$49,650current penalties
Mar 31, 2025last inspection

OSHA has inspected Lithko Contracting, LLC 6 times in Oklahoma since 2011.

The latest one began on Mar 31, 2025 on a referral, in Oklahoma City; the case is still open.

Those inspections ended with 3 citation items: 3 serious.

Penalties were first proposed at $49,650 and still stand at $49,650.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Lithko Contracting, LLC averages $49,650 (1 cited inspection).

It reported 1 severe injury to OSHA since 2015.

Lithko Contracting, LLC: OSHA citation items per year, 2011 to 2025
Citation items per year, by inspection date.

Want to know if OSHA cites Lithko Contracting, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348145939 OPENED MAR 31, 2025Open

Referral · Partial · Safety · 2,056 employees at the site · Open

400 N E.k. Gaylord Blvd, Oklahoma City, OK 73116 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.502(d)(15) · Fall protection systems
Serious$16,550$16,550Sep 23, 2025Contested
Citation 1, item 2
29 CFR 1926.703(a)(1) · Requirements for cast-in-place concrete
Serious$16,550$16,550Sep 23, 2025Contested
Citation 1, item 3
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Serious$16,550$16,550Sep 23, 2025Contested

Inspection 347110819 OPENED NOV 15, 2023Closed

Unprogrammed other · Partial · Safety · 4,800 employees at the site · Closed Mar 18, 2024

4924 S. Memorial Dr., Tulsa, OK 74145 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342577343 OPENED AUG 23, 2017Closed

Unprogrammed other · Partial · Safety · 1,200 employees at the site · Closed Aug 25, 2017

760 W. 4th Ave, Stillwater, OK 74074 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 337567218 OPENED NOV 13, 2012Closed

Unprogrammed other · Complete · Safety · 70 employees at the site · Closed Nov 14, 2012

3499 Main Street, Pryor, OK 74361 · Other Heavy and Civil Engineering Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 335613980 OPENED AUG 1, 2012Closed

Planned · Complete · Safety · 4 employees at the site · Closed Aug 2, 2012

302 S. Grand Blvd., Enid, OK 73701 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 314929589 OPENED JAN 21, 2011Closed

Planned · Complete · Safety · 4 employees at the site · Closed Jan 24, 2011

1330 Jenkins Ave., Norman, OK 73019 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Mar 28, 2025, Oklahoma City: Hospitalization · fractures · head and extremities

An employee was removing rigging at the top of a concrete form. The form collapsed and the employee fell with the form to the ground. The form landed on the employee's leg. The employee sustained fractures to their jaw and femur.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.502(d)(15)

(15) Anchorages used for attachment of personal fall arrest equipment shall be independent of any anchorage being used to support or suspend platforms and capable of supporting at least 5,000 pounds (22.2 kN) per employee attached, or shall be designed, installed, and used as follows:

29 CFR 1926.703 · Requirements for cast-in-place concrete

29 CFR 1926.703(a)(1)

(a) General requirements for formwork. (1) Formwork shall be designed, fabricated, erected, supported, braced and maintained so that it will be capable of supporting without failure all vertical and lateral loads that may reasonably be anticipated to be applied to the formwork. Formwork which is designed, fabricated, erected, supported, braced and maintained in conformance with the appendix to this section will be deemed to meet the requirements of this paragraph.

Other poured concrete foundation and structure contractors employers in Oklahoma

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.