OSHA SearchOSHA records by employer

Little Kading Construction Co Inc.: OSHA inspections and violations

Newton, Iowa · New Multifamily Housing Construction (except For-Sale Builders) · NAICS 236116

3inspections
9citation items
$3,300current penalties
Mar 8, 2016last inspection

Since 2002, OSHA inspectors have visited Little Kading Construction Co Inc. in Iowa 3 times.

The most recent inspection opened on Mar 8, 2016 after a complaint, in Osceola.

In all, OSHA issued 9 citation items: 8 serious and 1 other-than-serious.

The proposed penalties came to $6,300; today they stand at $3,300, 48% less.

The rule cited most here is 1926.405 (job-site wiring), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Little Kading Construction Co Inc. averages $1,500 across 1 cited inspection.

Little Kading Construction Co Inc.: OSHA citation items per year, 2002 to 2016
Citation items per year, by inspection date.

Iowa · latest 90 days of OSHA records

68employers cited

Get notified the morning OSHA posts each new citation in Iowa: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Iowa

Checking a subcontractor, a client or your own company? Watch Little Kading Construction Co Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341309565 OPENED MAR 8, 2016Closed

Complaint · Partial · Safety · 3 employees at the site · Closed May 26, 2016

1800 Block Of Daisy Lane, Osceola, IA 50213 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$750$375May 12, 2016Final
Citation 1, item 1b
29 CFR 1926.405(a)(2)(ii)(b) · Job-site wiring
Serious$0$0May 12, 2016Final
Citation 1, item 2
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$750$375May 12, 2016Final
Citation 1, item 3
29 CFR 1926.405(d) · Job-site wiring
Serious$1,500$750May 12, 2016Final

Inspection 314414731 OPENED MAR 30, 2010Closed

Referral · Partial · Safety · 6 employees at the site · Closed May 10, 2010

S. 8th Avenue And 1st Street, Newton, IA 50208 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,050$1,050Apr 16, 2010Closed

Inspection 304789480 OPENED FEB 11, 2002Closed

Planned · Complete · Safety · 7 employees at the site · Closed Mar 29, 2002

1000 Block Of 1st Ave. West, Newton, IA 50208 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$750$200Mar 4, 2002Closed
Citation 1, item 2
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$750$200Mar 4, 2002Closed
Citation 1, item 3
29 CFR 1926.405(g)(2)(iii) · Job-site wiring
Serious$750$350Mar 4, 2002Closed
Citation 2, item 1
29 CFR 1926.451(f)(16) · Scaffolds, general requirements
Other-than-serious$0$0Mar 4, 2002Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(2)

(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(i)

(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.

29 CFR 1926.404(f)(6)

(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

Other new multifamily housing construction (except for-sale builders) employers in Iowa

Alert subscribers get notified of each newly cited employer in Iowa the morning it is posted. See the alert plans.