OSHA SearchOSHA records by employer

Little Wolf Automotive, LLC: OSHA inspections and violations

Rothschild, Wisconsin · General Automotive Repair · NAICS 811111

2inspections
15citation items
$21,184current penalties
May 15, 2025last inspection

OSHA has inspected Little Wolf Automotive, LLC 2 times in Wisconsin since 2025.

The latest one began on May 15, 2025 after a complaint, in Rothschild.

Those inspections ended with 15 citation items: 15 serious.

Penalties were first proposed at $42,372 and now stand at $21,184, 50% lower after settlements or reviews.

Electrical wiring methods comes up most often in these citations: 3 items under 1910.305.

How that compares: the median penalty per cited inspection for repair and personal services employers since 2015 is $1,200, and Little Wolf Automotive, LLC averages $10,592 (2 cited inspections).

Little Wolf Automotive, LLC: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

214employers cited

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Little Wolf Automotive, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348250408 OPENED MAY 15, 2025Closed

Complaint · Partial · Safety · 50 employees at the site · Closed Jun 4, 2026

1133 East Grand Avenue, Rothschild, WI 54474 · General Automotive Repair · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.28(b)(8) · Fall protection in general industry
Serious$5,296$2,648Sep 30, 2025Final
Citation 1, item 2a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$6,621$3,310Sep 30, 2025Final
Citation 1, item 2b
29 CFR 1910.305(g)(1)(iv) · Electrical wiring methods
Serious$0$0Sep 30, 2025Final
Citation 1, item 2c
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$0$0Sep 30, 2025Final
Citation 1, item 2d
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$0$0Sep 30, 2025Final
Citation 1, item 2e
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Serious$0$0Sep 30, 2025Final
Citation 1, item 3
29 CFR 1910.307(c)(3) · Hazardous (classified) locations
Serious$9,268$4,634Sep 30, 2025Final

Inspection 348250721 OPENED MAY 15, 2025Closed

Complaint · Partial · Health · 6 employees at the site · Closed Jun 4, 2026

1133 East Grand Avenue, Rothschild, WI 54474 · General Automotive Repair · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.106(e)(2)(ii)(b)(1) · Flammable liquids
Serious$6,621$3,310Sep 30, 2025Final
Citation 1, item 1b
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$0$0Sep 30, 2025Final
Citation 1, item 2a
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Serious$7,945$3,972Sep 30, 2025Final
Citation 1, item 2b
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$0$0Sep 30, 2025Final
Citation 1, item 2c
29 CFR 1910.151(c) · First aid and eyewash
Serious$0$0Sep 30, 2025Final
Citation 1, item 3a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$6,621$3,310Sep 30, 2025Final
Citation 1, item 3b
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$0$0Sep 30, 2025Final
Citation 1, item 3c
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Sep 30, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(2)(ii)(b)(1)

(ii) Containers. Flammable liquids shall be stored in tanks or closed containers.

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.307 · Hazardous (classified) locations

29 CFR 1910.334 · Using electrical equipment

Other general automotive repair employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.