Inspection 343628970 OPENED NOV 29, 2018Closed
1000 Gateway Commons, Scarborough, ME 04074 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Scarborough, Maine · New Multifamily Housing Construction (except For-Sale Builders) · NAICS 236116
Since 2018, OSHA inspectors have visited Live Oak Contracting in Maine 2 times.
The most recent inspection opened on Nov 29, 2018 as a planned inspection, in Scarborough.
In all, OSHA issued 4 citation items: 4 other-than-serious.
The penalties, $29,100 in total, stand where OSHA first set them.
The rule cited most here is 1926.501 (fall protection in construction), 2 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Live Oak Contracting averages $29,100 across 1 cited inspection.
Maine · latest 90 days of OSHA records
33employers cited
Get notified the morning OSHA posts each new citation in Maine: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Maine
Checking a subcontractor, a client or your own company? Watch Live Oak Contracting and get notified the morning OSHA posts a new citation for it.
Watch this company1000 Gateway Commons, Scarborough, ME 04074 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1000 Gateway Blvd, Scarborough, ME 04070 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.34(a) · Means of egress |
Other-than-serious | $4,656 | $4,656 | Jul 31, 2018 | Final |
| Citation 1, item 2 29 CFR 1926.405(a)(2)(ii)(i) · Job-site wiring |
Other-than-serious | $8,148 | $8,148 | Jul 31, 2018 | Final |
| Citation 1, item 3 29 CFR 1926.501(b)(1) · Fall protection in construction |
Other-than-serious | $8,148 | $8,148 | Jul 31, 2018 | Final |
| Citation 1, item 4 29 CFR 1926.501(b)(14) · Fall protection in construction |
Other-than-serious | $8,148 | $8,148 | Jul 31, 2018 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.34(a)
(a) General. In every building or structure exits shall be so arranged and maintained as to provide free and unobstructed egress from all parts of the building or structure at all times when it is occupied. No lock or fastening to prevent free escape from the inside of any building shall be installed except in mental, penal, or corrective institutions where supervisory personnel is continually on duty and effective provisions are made to remove occupants in case of fire or other emergency.
29 CFR 1926.405(a)(2)(ii)(i)
(iii) Guarding. For temporary wiring over 600 volts, nominal, fencing, barriers, or other effective means shall be provided to prevent access of other than authorized and qualified personnel.
29 CFR 1926.501(b)(1)
(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.
Alert subscribers get notified of each newly cited employer in Maine the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.