OSHA SearchOSHA records by employer

LMP Construction, Inc.: OSHA inspections and violations

Cranston, Rhode Island · Roofing Contractors · NAICS 238160

5inspections
10citation items
$23,530current penalties
Aug 18, 2015last inspection

OSHA has inspected LMP Construction, Inc. 5 times in Rhode Island since 2008.

The latest one began on Aug 18, 2015 after a complaint, in Providence.

Those inspections ended with 10 citation items: 5 serious, 3 repeat and 2 other-than-serious.

Penalties were first proposed at $38,360 and now stand at $23,530, 39% lower after settlements or reviews.

Fall protection in construction comes up most often in these citations: 5 items under 1926.501.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and LMP Construction, Inc. averages $16,280 (1 cited inspection).

LMP Construction, Inc.: OSHA citation items per year, 2008 to 2015
Citation items per year, by inspection date.

Rhode Island · latest 90 days of OSHA records

84employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Rhode Island: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Rhode Island

Checking a subcontractor, a client or your own company? Watch LMP Construction, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340857317 OPENED AUG 18, 2015Closed

Complaint · Partial · Safety · 8 employees at the site · Closed Oct 25, 2017

460 Charles Street, Providence, RI 02905 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.416(e)(1) · Electrical safety in construction
Serious$2,200$2,200Aug 31, 2015Final
Citation 1, item 2
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Serious$3,080$3,080Aug 31, 2015Final
Citation 2, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Repeat$11,000$11,000Aug 31, 2015Final

Inspection 339217572 OPENED JUL 17, 2013Closed

Planned · Partial · Safety · 5 employees at the site · Closed Sep 9, 2013

560 Mineral Spring Ave, Pawtucket, RI 02860 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Other-than-serious$2,000$0Aug 20, 2013Final

Inspection 314918327 OPENED JUL 13, 2011Closed

Unprogrammed other · Partial · Safety · 4 employees at the site · Closed Aug 23, 2012

6 Carol Drive, Lincoln, RI 02865 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(16) · Ladders in construction
Other-than-serious$1,980$0Oct 28, 2011Closed
Citation 2, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Repeat$7,000$2,500Oct 28, 2011Closed
Citation 2, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Repeat$6,600$2,500Oct 28, 2011Closed

Inspection 312340540 OPENED JAN 13, 2009Closed

Unprogrammed other · Complete · Safety · 10 employees at the site · Closed Jul 2, 2009

177 Washington Rd., Barrington, RI 02806 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$2,000$1,000Feb 10, 2009Closed
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$1,000$500Feb 10, 2009Closed

Inspection 312339286 OPENED NOV 12, 2008Closed

Referral · Complete · Safety · 3 employees at the site · Closed Jan 6, 2009

866 Park Ave., Cranston, RI 02910 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$1,500$750Nov 19, 2008Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(e)(1)

(e) Cords and cables. (1) Worn or frayed electric cords or cables shall not be used.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

Other roofing contractors employers in Rhode Island

Alert subscribers get notified of each newly cited employer in Rhode Island the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.