OSHA SearchOSHA records by employer

LMR Plastering: OSHA inspections and violations

Bellaire, Texas · Brick, Stone, and Related Construction Material Merchant Wholesalers · NAICS 423320

1inspections
3citation items
$4,500current penalties
Nov 3, 2015last inspection

OSHA inspectors have visited LMR Plastering in Texas one time.

It opened on Nov 3, 2015 as a planned inspection, in Bellaire.

In all, OSHA issued 3 citation items: 3 serious.

The penalties, $4,500 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.

Among wholesale employers, the typical cited inspection since 2015 ends with a $3,425 penalty. LMR Plastering averages $4,500 across 1 cited inspection.

LMR Plastering: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Want to know if OSHA cites LMR Plastering again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341032605 OPENED NOV 3, 2015Closed

Planned · Partial · Safety · 6 employees at the site · Closed Jul 16, 2019

4512 Maple St, Bellaire, TX 77401 · Brick, Stone, and Related Construction Material Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,800$2,800Nov 19, 2015Final
Citation 1, item 2
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Nov 19, 2015Final
Citation 1, item 3
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Serious$1,700$1,700Nov 19, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.

29 CFR 1926.451(h)(2)(ii)

(ii) A toeboard shall be erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below, except on float (ship) scaffolds where an edging of 3/4 × 1 1/2 inch (2 × 4 cm) wood or equivalent may be used in lieu of toeboards;

Other brick, stone, and related construction material merchant wholesalers employers in Texas