OSHA SearchOSHA records by employer

Local Boston Masonry and Construction Corp: OSHA inspections and violations

Belmont, Massachusetts · Poured Concrete Foundation and Structure Contractors · NAICS 238110

1inspections
3citation items
$4,688current penalties
Apr 13, 2023last inspection

Local Boston Masonry and Construction Corp has one OSHA inspection on record in Massachusetts.

OSHA opened it on Apr 13, 2023 on a referral, in Belmont.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $4,688 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.651, excavations (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Local Boston Masonry and Construction Corp averages $4,688 over 1 cited inspection in that time.

Local Boston Masonry and Construction Corp: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

256employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch Local Boston Masonry and Construction Corp and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346631823 OPENED APR 13, 2023Closed

Referral · Partial · Safety · 3 employees at the site · Closed Jan 8, 2026

47 Hawthorne Street, Belmont, MA 02478 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.651(c)(2) · Excavations
Serious$4,688$4,688Aug 15, 2023Final
Citation 1, item 1b
29 CFR 1926.651(i)(1) · Excavations
Serious$0$0Aug 15, 2023Final
Citation 1, item 1c
29 CFR 1926.651(j)(2) · Excavations
Serious$0$0Aug 15, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(i)(1)

(i) Stability of adjacent structures. (1) Where the stability of adjoining buildings, walls, or other structures is endangered by excavation operations, support systems such as shoring, bracing, or underpinning shall be provided to ensure the stability of such structures for the protection of employees.

29 CFR 1926.651(j)(2)

(2) Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.

Other poured concrete foundation and structure contractors employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.