OSHA SearchOSHA records by employer

Locklear Boring Inc: OSHA inspections and violations

Chester, South Carolina · Water and Sewer Line and Related Structures Construction · NAICS 237110

1inspections
3citation items
$6,900current penalties
Nov 15, 2018last inspection

Locklear Boring Inc has one OSHA inspection on record in South Carolina.

OSHA opened it on Nov 15, 2018 on a referral, in Chester.

From that inspection OSHA issued 3 citation items: 2 serious and 1 other-than-serious.

OSHA proposed $6,900 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.1203, confined spaces in construction: general requirements (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,078. Locklear Boring Inc averages $6,900 over 1 cited inspection in that time.

Locklear Boring Inc: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Want to know if OSHA cites Locklear Boring Inc again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 343640157 OPENED NOV 15, 2018Closed

Referral · Complete · Safety · 5 employees at the site · Closed Aug 13, 2019

Hwy 9 Between 1759 Lancaster Hwy And Cederhurst, Chester, SC 29706 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$2,250$2,250Mar 22, 2019Final
Citation 1, item 2
29 CFR 1926.1203(d) · Confined Spaces in Construction: general requirements
Serious$4,200$4,200Mar 22, 2019Final
Citation 2, item 1
29 CFR 1926.1203(a) · Confined Spaces in Construction: general requirements
Other-than-serious$450$450Mar 22, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1203 · Confined Spaces in Construction: general requirements

29 CFR 1926.1203(a)

(a) Before it begins work at a worksite, each employer must ensure that a competent person identifies all confined spaces in which one or more of the employees it directs may work, and identifies each space that is a permit space, through consideration and evaluation of the elements of that space, including testing as necessary.

29 CFR 1926.1203(d)

(d) If any employer decides that employees it directs will enter a permit space, that employer must have a written permit space program that complies with § 1926.1204 implemented at the construction site. The written program must be made available prior to and during entry operations for inspection by employees and their authorized representatives.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

Other water and sewer line and related structures construction employers in South Carolina

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.