OSHA SearchOSHA records by employer

Locust Lane Farms, Inc.: OSHA inspections and violations

Laurel, Maryland · Water and Sewer Line and Related Structures Construction · NAICS 237110

3inspections
12citation items
$3,275current penalties
Jul 22, 2022last inspection

Since 2010, OSHA inspectors have visited Locust Lane Farms, Inc. in Maryland 3 times.

The most recent inspection opened on Jul 22, 2022 as a planned inspection, in Fort Meade.

In all, OSHA issued 12 citation items: 8 serious and 4 other-than-serious.

The proposed penalties came to $6,225; today they stand at $3,275, 47% less.

The rule cited most here is 1926.652 (trench protection), 5 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Locust Lane Farms, Inc. averages $1,638 across 2 cited inspections.

Locust Lane Farms, Inc.: OSHA citation items per year, 2010 to 2022
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

178employers cited

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Locust Lane Farms, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346104250 OPENED JUL 22, 2022Closed

Planned · Complete · Safety · 6 employees at the site · Closed Oct 12, 2022

1100 Clark Road, Fort Meade, MD 20755 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Serious$1,750$744Sep 12, 2022Final
Citation 1, item 2a
29 CFR 1926.651(k)(1) · Excavations
Serious$1,750$1,041Sep 12, 2022Final
Citation 1, item 2b
29 CFR 1926.652(a)(1) · Trench protection
Serious$0$0Sep 12, 2022Final
Citation 1, item 2c
29 CFR 1926.652(g)(1)(ii) · Trench protection
Serious$0$0Sep 12, 2022Final
Citation 1, item 2d
29 CFR 1926.652(g)(2) · Trench protection
Serious$0$0Sep 12, 2022Final
Citation 1, item 3
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$1,500$765Sep 12, 2022Final
Citation 2, item 1
29 CFR 1926.652(c)(2)(iii) · Trench protection
Other-than-serious$0$0Sep 12, 2022Final
Citation 2, item 2
29 CFR 05-503(C)(1)(I)
Other-than-serious$0$0Sep 12, 2022Final

Inspection 346054232 OPENED JUN 30, 2022Closed

Planned · Complete · Safety · 5 employees at the site · Closed Sep 19, 2022

Intersection Of 8490 Washington Boulevard And Ridgely?s Run Road, Savage, MD 20763 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2a
29 CFR 1926.651(k)(1) · Excavations
Serious$1,225$725Aug 12, 2022Final
Citation 1, item 2b
29 CFR 1926.652(a)(1) · Trench protection
Serious$0$0Aug 12, 2022Final
Citation 2, item 1
29 CFR 1926.651(c)(2) · Excavations
Other-than-serious$0$0Aug 12, 2022Final
Citation 2, item 2
29 CFR 5-503(C)(1)(I)
Other-than-serious$0$0Aug 12, 2022Final

Inspection 314684242 OPENED JUL 13, 2010Closed

Planned · Complete · Safety · 2 employees at the site · Closed Jul 16, 2010

7120 Contee Road, Laurel, MD 20707 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.652 · Trench protection

Other water and sewer line and related structures construction employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.