OSHA SearchOSHA records by employer

Lodgic Hospitality LLC: OSHA inspections and violations

Texas City, Texas · Commercial and Institutional Building Construction · NAICS 236220

2inspections
3citation items
$2,660current penalties
Jun 13, 2019last inspection

Since 2018, OSHA inspectors have visited Lodgic Hospitality LLC in Texas 2 times.

The most recent inspection opened on Jun 13, 2019, in Texas City.

In all, OSHA issued 3 citation items: 3 serious.

The proposed penalties came to $4,434; today they stand at $2,660, 40% less.

The rule cited most here is 1926.150 (fire protection), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Lodgic Hospitality LLC averages $2,660 across 1 cited inspection.

Lodgic Hospitality LLC: OSHA citation items per year, 2018 to 2019
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Lodgic Hospitality LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344077946 OPENED JUN 13, 2019Closed

Unprogrammed other · Partial · Safety · 12 employees at the site · Closed Jul 31, 2019

130202 Outlet Blvd, Texas City, TX 77590 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343359782 OPENED AUG 3, 2018Closed

Planned · Complete · Safety · 1 employee at the site · Closed Nov 1, 2018

13202 Outlets Blvd, Texas City, TX 77591 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.25(a) · Housekeeping
Serious$2,217$1,330Sep 19, 2018Final
Citation 1, item 2a
29 CFR 1926.150(c)(1)(i) · Fire protection
Serious$2,217$1,330Sep 19, 2018Final
Citation 1, item 2b
29 CFR 1926.150(c)(1)(vi) · Fire protection
Serious$0$0Sep 19, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(i)

(c) Portable firefighting equipment—(1) Fire extinguishers and small hose lines. (i) A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the protected building area, or major fraction thereof. Travel distance from any point of the protected area to the nearest fire extinguisher shall not exceed 100 feet.

29 CFR 1926.150(c)(1)(vi)

(vi) A fire extinguisher, rated not less than 10B, shall be provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas are being used on the jobsite. This requirement does not apply to the integral fuel tanks of motor vehicles.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.25(a)

(a) During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, shall be kept cleared from work areas, passageways, and stairs, in and around buildings or other structures.