Inspection 349122275 OPENED AUG 18, 2026Open
112 Welpine Ridge Road, Pendleton, SC 29670 · All Other Transportation Equipment Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
Pendleton, South Carolina · All Other Transportation Equipment Manufacturing · NAICS 336999
Since 2025, OSHA inspectors have visited Logiclean in South Carolina 2 times.
The most recent inspection opened on Aug 18, 2026 to follow up on an earlier case, in Pendleton and is still open.
In all, OSHA issued 4 citation items: 4 serious.
The penalties, $14,000 in total, stand where OSHA first set them.
The rule cited most here is 1910.23 (ladders in general industry), 2 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Logiclean averages $14,000 across 1 cited inspection.
Want to know if OSHA cites Logiclean again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this company112 Welpine Ridge Road, Pendleton, SC 29670 · All Other Transportation Equipment Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
112 Welpine Ridge Road, Pendleton, SC 29670 · All Other Transportation Equipment Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(b)(6) · Ladders in general industry |
Serious | $3,500 | $3,500 | Dec 11, 2025 | Final |
| Citation 1, item 2 29 CFR 1910.23(c)(5) · Ladders in general industry |
Serious | $3,500 | $3,500 | Dec 11, 2025 | Final |
| Citation 1, item 3 29 CFR 1910.146(c)(4) · Permit-required confined spaces |
Serious | $3,500 | $3,500 | Dec 11, 2025 | Final |
| Citation 1, item 4 29 CFR 1910.146(g)(4) · Permit-required confined spaces |
Serious | $3,500 | $3,500 | Dec 11, 2025 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.146(c)(4)
(4) If the employer decides that its employees will enter permit spaces, the employer shall develop and implement a written permit space program that complies with this section. The written program shall be available for inspection by employees and their authorized representatives.
29 CFR 1910.146(g)(4)
(4) The employer shall certify that the training required by paragraphs (g)(1) through (g)(3) of this section has been accomplished. The certification shall contain each employee's name, the signatures or initials of the trainers, and the dates of training. The certification shall be available for inspection by employees and their authorized representatives.
29 CFR 1910.23(b)(6)
(6) Metal ladders are made with corrosion-resistant material or protected against corrosion;
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.