OSHA SearchOSHA records by employer

Longoria Masonry: OSHA inspections and violations

San Antonio, Texas · Masonry Contractors · NAICS 238140

5inspections
13citation items
$9,270current penalties
Mar 7, 2018last inspection

Longoria Masonry has 5 OSHA inspections on record in Texas, the first in 2003.

OSHA's last visit started on Mar 7, 2018 as a planned inspection, in San Antonio.

Across those inspections OSHA issued 13 citation items: 13 serious.

OSHA proposed $16,048 in penalties. After settlements and reviews the total is $9,270, down 42%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (10 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Longoria Masonry averages $4,500 over 1 cited inspection in that time.

Longoria Masonry: OSHA citation items per year, 2003 to 2018
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

13 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Longoria Masonry and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343017075 OPENED MAR 7, 2018Closed

Planned · Partial · Safety · 3 employees at the site · Closed Feb 28, 2024

146 Cedar Street, San Antonio, TX 78209 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,217$1,000Apr 27, 2018Final
Citation 1, item 2
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$2,217$1,000Apr 27, 2018Final
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,217$1,000Apr 27, 2018Final
Citation 1, item 4a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,217$1,500Apr 27, 2018Final
Citation 1, item 4b
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$0$0Apr 27, 2018Final

Inspection 337297618 OPENED NOV 7, 2012Closed

Unprogrammed other · Partial · Safety · 6 employees at the site · Closed Nov 27, 2013

18300 Hwy 3, Webster, TX 77598 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,800$1,680Feb 7, 2013Final

Inspection 311313035 OPENED APR 15, 2008Closed

Planned · Complete · Safety · 15 employees at the site · Closed May 30, 2008

501 S. Austin Ave., Georgetown, TX 78626 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(c) · Tools—Hand and Power: general requirements
Serious$600$360Apr 17, 2008Closed

Inspection 311311765 OPENED NOV 1, 2007Closed

Planned · Partial · Safety · 3 employees at the site · Closed May 29, 2008

Houston St & New Braunfels St, San Antonio, TX 78220 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$360$360Feb 13, 2008Closed
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$360$360Feb 13, 2008Closed
Citation 1, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$360$360Feb 13, 2008Closed

Inspection 306062431 OPENED APR 25, 2003Closed

Referral · Partial · Safety · 10 employees at the site · Closed Jan 8, 2004

H281 And Encino Rio Rd., San Antonio, TX 78248 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$600$600May 12, 2003Closed
Citation 1, item 2
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,050$525May 12, 2003Closed
Citation 1, item 3
29 CFR 1926.451(g)(1)(v) · Scaffolds, general requirements
Serious$1,050$525May 12, 2003Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.300(c)

(c) Personal protective equipment. Employees using hand and power tools and exposed to the hazard of falling, flying, abrasive, and splashing objects, or exposed to harmful dusts, fumes, mists, vapors, or gases shall be provided with the particular personal protective equipment necessary to protect them from the hazard. All personal protective equipment shall meet the requirements and be maintained according to subparts D and E of this part.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.501 · Fall protection in construction

Other masonry contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.