OSHA SearchOSHA records by employer

Lonza, Incorporated: OSHA inspections and violations

Williamsport, Pennsylvania · Other Basic Inorganic Chemical Manufacturing · NAICS 325188

8inspections
7citation items
$5,305current penalties
Feb 6, 2015last inspection

OSHA has inspected Lonza, Incorporated 8 times in Pennsylvania since 1991.

The latest one began on Feb 6, 2015 on a referral, in Williamsport.

Those inspections ended with 7 citation items: 4 serious and 3 other-than-serious.

Penalties were first proposed at $7,200 and now stand at $5,305, 26% lower after settlements or reviews.

Walking-working surfaces comes up most often in these citations: 2 items under 1910.22.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Lonza, Incorporated averages $3,825 (1 cited inspection).

Lonza, Incorporated also files yearly injury logs with OSHA, summarized below.

It reported 1 severe injury to OSHA since 2015.

Lonza, Incorporated: OSHA citation items per year, 1991 to 2015
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

297employers cited

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Lonza, Incorporated and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340319276 OPENED FEB 6, 2015Closed

Referral · Partial · Safety · 145 employees at the site · Closed Jun 2, 2015

3500 Trenton Avenue, Williamsport, PA 17701 · All Other Basic Organic Chemical Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$5,100$3,825May 8, 2015Final

Inspection 312286412 OPENED JUL 29, 2008Closed

Referral · Partial · Health · 160 employees at the site · Closed Oct 17, 2008

3500 Trenton Ave., Williamsport, PA 17701 · Other Basic Inorganic Chemical Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.22(a)(2) · General requirements
Serious$975$680Sep 30, 2008Closed
Citation 1, item 1b
29 CFR 1910.22(a)(1) · General requirements
Serious$0$0Sep 30, 2008Closed

Inspection 305014359 OPENED AUG 20, 2002Closed

Complaint · Partial · Safety · 185 employees at the site · Closed Oct 8, 2002

900 River Road, Conshohocken, PA 19428 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 106470602 OPENED JAN 4, 1996Closed

Referral · Partial · Health · 165 employees at the site · Closed Feb 7, 1996

3500 Trenton Ave., Williamsport, PA 17701 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 17624073 OPENED MAY 1, 1995Closed

Complaint · Partial · Health · 160 employees at the site · Closed May 9, 1995

3500 Trenton Ave., Williamsport, PA 17701 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 17618935 OPENED DEC 9, 1994Closed

Complaint · Partial · Health · 165 employees at the site · Closed Feb 26, 1995

3500 Trenton Ave., Williamsport, PA 17701 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$1,125$800Dec 20, 1994Closed

Inspection 17619602 OPENED MAY 12, 1994Closed

Planned · Partial · Health · 160 employees at the site · Closed Jun 16, 1994

3500 Trenton Ave., Williamsport, PA 17701 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1047(d)(1)(i) · Ethylene oxide
Other-than-serious$0$0May 13, 1994Closed
Citation 1, item 2
29 CFR 1910.1047(d)(7)(i) · Ethylene oxide
Other-than-serious$0$0May 13, 1994Closed
Citation 1, item 3 Other-than-serious$0$0May 13, 1994Closed

Inspection 109368522 OPENED JUN 13, 1991Closed

Referral · Partial · Health · 155 employees at the site · Closed Aug 8, 1991

3500 Trenton Ave., Williamsport, PA 17701 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2020, the Williamsport site logged 0 recordable injuries or illnesses among about 145 workers: 0.0 per 100 full-time workers, against a median of 0.7 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Lonza Inc
Williamsport · 2020
145 000.00.7
Lonza, Inc.
Williamsport · 2018
140 522.60.7

Included with any plan: 3 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Feb 4, 2015, Williamsport: Hospitalization · fractures · elbow(s) and arms(s)

An employee fell 12 feet to the ground from the top of the top wagon, resulting in a broken left elbow. He was admitted to the hospital for surgery.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1047 · Ethylene oxide

29 CFR 1910.1047(d)(1)(i)

(d) Exposure monitoring—(1) General. (i) Determinations of employee exposure shall be made from breathing zone air samples that are representative of the 8-hour TWA and 15-minute short-term exposures of each employee.

29 CFR 1910.1047(d)(7)(i)

(7) Employee notification of monitoring results. (i) The employer must, within 15 working days after the receipt of the results of any monitoring performed under this section, notify each affected employee of these results either individually in writing or by posting the results in an appropriate location that is accessible to employees.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(a)

(a) Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.

29 CFR 1910.20

29 CFR 1910.22 · General requirements

29 CFR 1910.303 · Electrical equipment, general requirements

Other other basic inorganic chemical manufacturing employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.