OSHA SearchOSHA records by employer

Loredo Masonry: OSHA inspections and violations

San Antonio, Texas · Masonry Contractors · NAICS 238140

3inspections
6citation items
$16,193current penalties
Oct 31, 2022last inspection

Since 2003, OSHA inspectors have visited Loredo Masonry in Texas 3 times.

The most recent inspection opened on Oct 31, 2022 as a planned inspection, in Cibolo.

In all, OSHA issued 6 citation items: 6 serious.

The penalties, $16,193 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Loredo Masonry averages $16,193 across 1 cited inspection.

Loredo Masonry: OSHA citation items per year, 2003 to 2022
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

13 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Loredo Masonry and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346315864 OPENED OCT 31, 2022Closed

Planned · Partial · Safety · 5 employees at the site · Closed Nov 21, 2022

517 Fawn Dale, Cibolo, TX 78108 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344535950 OPENED JAN 2, 2020Closed

Planned · Partial · Safety · 2 employees at the site · Closed Apr 6, 2023

5111 Papalote Garden, Converse, TX 78109 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$2,313$2,313Apr 8, 2020Final
Citation 1, item 2a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$3,470$3,470Apr 8, 2020Final
Citation 1, item 2b
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$0$0Apr 8, 2020Final
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,470$3,470Apr 8, 2020Final
Citation 1, item 4
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$3,470$3,470Apr 8, 2020Final
Citation 1, item 5
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$3,470$3,470Apr 8, 2020Final

Inspection 306066580 OPENED DEC 4, 2003Closed

Planned · Partial · Safety · 4 employees at the site · Closed Mar 16, 2004

6418 Pelican Coral, San Antonio, TX 78244 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

29 CFR 1926.452 · Rules for each type of scaffold

Other masonry contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.