Lorrus Concrete LLC: OSHA inspections and violations

New Orleans, Louisiana · Poured Concrete Foundation and Structure Contractors · NAICS 238110

1inspections
3citation items
$5,674current penalties
Feb 13, 2025last inspection

OSHA has inspected Lorrus Concrete LLC once in Louisiana.

The inspection began on Feb 13, 2025 as a planned inspection, in New Orleans; the case is still open.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $5,674 and still stand at $5,674.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Lorrus Concrete LLC averages $5,674 (1 cited inspection).

Lorrus Concrete LLC: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Louisiana · latest 90 days of OSHA records

18employers cited

Get notified the morning OSHA posts each new citation in Louisiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Louisiana

Checking a subcontractor, a client or your own company? Watch Lorrus Concrete LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348043480 OPENED FEB 13, 2025Open

Planned · Partial · Safety · 10 employees at the site · Open

609 Jackson St, New Orleans, LA 70112 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$2,837$2,837Aug 12, 2025Final
Citation 1, item 2b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Aug 12, 2025Final
Citation 1, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,837$2,837Aug 12, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(1)

(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.