OSHA SearchOSHA records by employer

Los Angeles Engineering, Inc.: OSHA inspections and violations

Los Angeles, California · Water and Sewer Line and Related Structures Construction · NAICS 237110

7inspections
17citation items
$117,530current penalties
Sep 28, 2018last inspection

OSHA has inspected Los Angeles Engineering, Inc. 7 times in California since 1992.

The latest one began on Sep 28, 2018 after an accident, in Azusa.

Those inspections ended with 17 citation items: 5 serious, 1 repeat and 11 other-than-serious.

Penalties were first proposed at $168,360 and now stand at $117,530, 30% lower after settlements or reviews.

comes up most often in these citations: 3 items under 1541.1.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Los Angeles Engineering, Inc. averages $5,062 (3 cited inspections).

1 inspection on this page followed a fatal incident.

Los Angeles Engineering, Inc.: OSHA citation items per year, 1992 to 2018
Citation items per year, by inspection date.

California · latest 90 days of OSHA records

1,130employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in California: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in California

Checking a subcontractor, a client or your own company? Watch Los Angeles Engineering, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343498390 OPENED SEP 28, 2018Closed

Accident · Partial · Safety · 3 employees at the site · Closed Sep 10, 2020

5500 N. Cerritos, Azusa, CA 91702 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Incident on Sep 11, 2018: Employee partially amputates finger while pulling on length

At 3:00 p.m. on September 11, 2018, an employee was working to close of a work site for the day and asked a coworker to check the perimeter fence to ensure it was secure. The coworker notified the employee that a section needed to be tied together and asked if the employee had tie wire to secure the fence. The employee went to his work truck and brought a roll of tie wire to the location of the fence that needed tying. The employee laid the roll of wire on the ground and placed a foot on the roll to secure it in place and as he wrapped the free end around his left index finger to pull out a section of wire. Distracted by a discussion with the coworker, the employee did not remove his left finger from the wire as he pulled on the wire with his right hand. The pulling action tightened the wire around his left index finger and amputated half of the finger.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 342(A)
Other-than-serious$5,000$2,500Feb 7, 2019Final

Inspection 342807153 OPENED NOV 8, 2017Closed

Accident · Partial · Safety · 115 employees at the site · Closed Sep 15, 2021

Riverside Dr., Ontario, CA 91710 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1709(B)(2)
Other-than-serious$15,300$3,715May 7, 2018Final
Citation 2, item 1
29 CFR 1709(D)
Other-than-serious$15,300$3,715May 7, 2018Final
Citation 3, item 1
29 CFR 4999(H)
Other-than-serious$15,300$3,715May 7, 2018Final

Inspection 342720778 OPENED OCT 23, 2017Closed

Accident · Partial · Safety · 7 employees at the site · Closed Feb 10, 2021

N. Bristol & W. Washington, Santa Ana, CA 92706 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Incident on Oct 23, 2017: Employee is injured when an unsecured trench section collaps

At 12:30 p.m. on October 23, 2017, Employee #1, employed by a construction company, was working inside a tee-trench that measured 6.5 feet deep by 4 feet wide. He was connecting a new water pipe that had been installed. Most of the trench was shored, but one inside corner was not protected completely due to an electrical line obstruction. As Employee #1 bent down to examine the pipe, soil from the unshored area broke loose and struck the back of his head. His face struck the water pipe. Emergency services were called, and Employee #1 was transported to the hospital. He was treated for contusions and a laceration that required sutures and released the same day. At a later date, Employee #1 required additional treatment for pain management.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 3276(E)(3)
Other-than-serious$410$410Apr 12, 2018Final
Citation 1, item 2
29 CFR 5044(A)
Other-than-serious$305$305Apr 12, 2018Final
Citation 2, item 1 Other-than-serious$14,400$825Apr 12, 2018Final

Inspection 314864661 OPENED MAR 14, 2013Open

Accident · Partial · Safety · 5 employees at the site · Open

200 Temescal Canyon Rd., Los Angeles, CA 90272 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Incident on Mar 14, 2013 (fatal): One worker is killed, one is injured in trench collapse

At 1:00 p.m. on March 14, 2013, Employee #1 and Employee #2, of Los Angeles Engi neering Inc., a general engineering and pipeline construction company, were work ing on a pipeline construction project. They were excavating a trench for the pu rpose of installing steel reinforced concrete pipe for a storm drain. They were in a section of the trench that lacked any shoring or other protection and check ing the depth. The trench measured 14 feet deep. Coworker #1 was operating a bac khoe in the trench, excavating soil from a trench cave-in that had occurred alon g the south wall two hours earlier. Coworker #2, the supervisor, was in the imme diate area of the earlier collapse, operating a front loader atop the north wall of the trench at surface grade level. The north wall of the trench collapsed. I t collapsed directly on Employee #1, pushing him into the south wall of the tren ch and completely burying him. Employee #1 was killed. The collapsing trench pus hed Employee #2 against a trench shield in a shored section of the trench, buryi ng him to his thighs. Emergency personnel were called, and at 1:45 p.m. the Los Angeles Fire Department dispatched fire and rescue resources to the site. At 1:5 5 p.m., the Los Angeles Fire Department notified Cal/OSHA. Fire Department perso nnel exposed Employee #1's head and determined that he was dead. They began a re covery operation that lasted 7 hours. Employee#2 was extricated from the trench and transported by air ambulance to UCLA Ronald Reagan Medical Center, where he was hospitalized and treated for trauma to his legs, including one or more leg f ractures. Cal/OSHA, which immediately responded after being notified by the Los Angeles Fire Department, arrived at the site at 3:00 p.m. Cal/OSHA contacted the employer, fulfilling reporting requirements. Cal/OSHA's investigation determine d that Employees #1 and #2 were working in a 14-foot deep trench that was not pr otected from a cave-in by any protective systems or procedures. The trench in wh ich they were working had caved in two hours earlier. When the second cave-in oc curred, killing Employee #1 and seriously injuring Employee #1, their supervisor was in the immediate area and was in possession of engineering documents indica ting that employees must not work in the unprotected sections of the trench. ACC IDENT RELATED-SERIOUS CITATIONS ISSUED: Cal/OSHA planned to issue a Willful Seri ous Accident Related citation for a violation of T8 CCR 1541.1(a), a serious cit ation for a violation of 1541(k), and a serious citation for a violation of 1509 (a).

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 3395 F01
Other-than-serious$485$485Sep 13, 2013Contested
Citation 2, item 1
29 CFR 1509 A
Serious$5,850$5,850Sep 13, 2013Contested
Citation 3, item 1
29 CFR 1541 K01
Serious$24,300$24,300Sep 13, 2013Contested
Citation 4, item 1 Serious$70,000$70,000Sep 13, 2013Contested

Inspection 126202498 OPENED JUL 27, 2010Closed

Planned · Partial · Safety · 100 employees at the site · Closed Jul 28, 2010

230 1/2 Arno Way, Los Angeles, CA 90272 · Other Heavy and Civil Engineering Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 125892968 OPENED APR 16, 1998Closed

Accident · Partial · Safety · 10 employees at the site · Closed Aug 13, 1998

10124 Limonite Avenue, Pedley, CA 92509 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$1,375$1,375Apr 28, 1998Closed
Citation 2, item 1
29 CFR 1541 K02
Serious$135$135Apr 28, 1998Closed

Inspection 119847036 OPENED AUG 6, 1992Closed

Unprogrammed other · Complete · Safety · 4 employees at the site · Closed Jun 25, 1996

14005 E. Liveoak Ave., Irwindale, CA 91706 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 340
Repeat$50$50Aug 6, 1992Closed
Citation 1, item 2
29 CFR 1510 B
Other-than-serious$50$50Aug 6, 1992Closed
Citation 1, item 3
29 CFR 1524 A01
Other-than-serious$50$50Aug 6, 1992Closed
Citation 1, item 4
29 CFR 1524 A04
Other-than-serious$50$50Aug 6, 1992Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1541.1

Other water and sewer line and related structures construction employers in California

Alert subscribers get notified of each newly cited employer in California the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.