Inspection 317203099 OPENED JAN 28, 2014Closed
Accident · Partial · Safety · 4 employees at the site · Closed Nov 17, 2016
4239 Terrace St, Oakland, CA 94611 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
Incident on Jan 28, 2014: Roofer fractures chest in fall from unsecured ladder
At approximately 9:00 a.m. on January 28, 2014, Employee #1, employed by a roofi ng contractor, was part of a work crew engaged in a four-day re-roofing project on a three-story craftsman-style single family residence. Employee #1's immediat e task was to install roofing felt, nosing, and flashing on a section of roofing at a brow eave above a set of first floor windows. This work needed to be accom plished before Employee #1's supervisor could install shingles. The supervisor w as working directly above Employee #1 on the upper roof of the house. Employee # 1 was working from an extension ladder set up in the driveway along the side of the house. As he nailed in flashing, Employee #1 lost his balance. The ladder sl ipped, causing him to fall down and to his left. Employee #1 landed on the drive way surface, a fall height of approximately 11 feet. Employee #1's supervisor he ard Employee #1 yell as he fell, and from the supervisor's vantage point directl y above, witnessed the last few feet of Employee #1's fall. Emergency services w ere called, and the Oakland Fire Department responded. Employee #1 was transport ed to the hospital, where he was admitted and treated for a fractured chest. Thi s event was reported to Cal/OSHA by the Oakland Fire Department at 9:45 a.m. on January 28, 2014. A Cal/OSHA compliance officer arrived at the site and began an investigation at 1:35 p.m. on January 28, 2014, before the employer had the opp ortunity to contact Cal/OSHA as required. The investigation determined that the employer was a roofing contractor who had been in business for five generations and specialized in re-roofing projects. When the fall occurred, Employee #1 was installing the new flashing to the roof's brow eave. The base of the ladder from which he was working rested on a sloping concrete driveway, with scrap lumber p laced under the downhill foot of the ladder in an attempt to level the base. The feet of the ladder were not positively secured. The top of the ladder was resti ng against the wall just above the top of the window. The brow being re-roofed o verhung the wall approximately 12 inches at this location and was approximately 14 feet 2 inches directly above the driveway surface. At the corner of the house where the slope of the driveway leveled out to horizontal, the brow was approxi mately 16 feet 2 inches above the driveway. The slope of the driveway between th ese points was approximately 10 degrees. The ladder was not tied, blocked, held, or otherwise secured to prevent slipping. The investigation concluded that this event's main causal factor was failure to secure the ladder. Other contributing factors included the lack of effective training of the injured employee, and th e awkward positioning of the ladder on the sloping driveway and beneath the brow overhang.