OSHA SearchOSHA records by employer

Lowell Green Construction LLC: OSHA inspections and violations

Magnolia, Iowa · Industrial Building Construction · NAICS 236210

1inspections
5citation items
$3,000current penalties
Mar 28, 2017last inspection

OSHA has inspected Lowell Green Construction LLC once in Iowa.

The inspection began on Mar 28, 2017 on a referral, in Magnolia.

That inspection ended with 5 citation items: 5 serious.

Penalties were first proposed at $3,750 and now stand at $3,000, 20% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 4 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Lowell Green Construction LLC averages $3,000 (1 cited inspection).

Lowell Green Construction LLC: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Iowa · latest 90 days of OSHA records

66employers cited

Get notified the morning OSHA posts each new citation in Iowa: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Iowa

Checking a subcontractor, a client or your own company? Watch Lowell Green Construction LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342209053 OPENED MAR 28, 2017Closed

Referral · Partial · Safety · 2 employees at the site · Closed May 18, 2017

2162 Malibu Lane, Magnolia, IA 51550 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

Incident on Mar 16, 2017: Two employees are injured in fall when scaffold collapses

At approximately 1:45 p.m. on March 16, 2017, Employee #1 and #2 were work from a carpenters bracket scaffolding installing fascia trim so they could start installing roofing panels. The bracket from the scaffolding pulled off and both employees fell 16 feet to the ground. Both employees were hospitalized and treated for unspecified broken bones.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(a)(1) · Scaffolds, general requirements
Serious$750$750Apr 18, 2017Final
Citation 1, item 1b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$750$0Apr 18, 2017Final
Citation 1, item 2
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$750$750Apr 18, 2017Final
Citation 1, item 3
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$750$750Apr 18, 2017Final
Citation 1, item 5
29 CFR 1926.452(g)(1) · Rules for each type of scaffold
Serious$750$750Apr 18, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(1)

(a) Capacity. (1) Except as provided in paragraphs (a)(2), (a)(3), (a)(4), (a)(5) and (g) of this section, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it.

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

29 CFR 1926.452 · Rules for each type of scaffold

Other industrial building construction employers in Iowa

Alert subscribers get notified of each newly cited employer in Iowa the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.