OSHA SearchOSHA records by employer

Lowery Masonry, LLC: OSHA inspections and violations

Houston, Texas · Masonry Contractors · NAICS 238140

5inspections
17citation items
$20,532current penalties
Mar 3, 2021last inspection

Lowery Masonry, LLC has 5 OSHA inspections on record in Texas, the first in 2003.

OSHA's last visit started on Mar 3, 2021 as a planned inspection, in Pearland.

Across those inspections OSHA issued 17 citation items: 12 serious, 3 repeat and 2 other-than-serious.

OSHA proposed $48,301 in penalties. After settlements and reviews the total is $20,532, down 57%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (14 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Lowery Masonry, LLC averages $2,341 over 1 cited inspection in that time.

Lowery Masonry, LLC also files yearly injury logs with OSHA, summarized below.

Lowery Masonry, LLC: OSHA citation items per year, 2003 to 2021
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

13 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Lowery Masonry, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345174049 OPENED MAR 3, 2021Closed

Planned · Partial · Safety · 7 employees at the site · Closed May 17, 2021

2047-2057 Pearland Pkwy, Pearland, TX 77581 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$3,901$2,341Mar 29, 2021Final

Inspection 310261201 OPENED FEB 26, 2007Closed

Planned · Partial · Health · 40 employees at the site · Closed Jun 4, 2007

2821 W Parkwood, Friendswood, TX 77546 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(a)(4) · Scaffolds, general requirements
Serious$2,500$1,500May 15, 2007Closed

Inspection 308317171 OPENED SEP 15, 2005Closed

Unprogrammed other · Complete · Safety · 10 employees at the site · Closed Feb 16, 2006

1307 Fairmont Parkway, La Porte, TX 77571 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$900$900Feb 1, 2006Closed
Citation 2, item 1
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Repeat$15,000$4,500Feb 1, 2006Closed
Citation 2, item 2
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Repeat$15,000$4,500Feb 1, 2006Closed
Citation 2, item 3
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Repeat$4,500$2,500Feb 1, 2006Closed

Inspection 306478157 OPENED JAN 26, 2004Closed

Unprogrammed other · Complete · Health · 7 employees at the site · Closed Mar 17, 2004

15500 El Camino Real, Houston, TX 77062 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 3
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Other-than-serious$900$0Feb 20, 2004Closed
Citation 1, item 4a
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$900$900Feb 20, 2004Closed
Citation 1, item 4b
29 CFR 1926.451(a)(1) · Scaffolds, general requirements
Serious$0$0Feb 20, 2004Closed
Citation 1, item 4c
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$0$0Feb 20, 2004Closed
Citation 1, item 5
29 CFR 1926.454(b) · Scaffold training
Other-than-serious$900$0Feb 20, 2004Closed
Citation 1, item 6a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$0$900Feb 20, 2004Closed
Citation 1, item 6b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Feb 20, 2004Closed
Citation 2, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$2,400$1,651Feb 20, 2004Closed

Inspection 304577372 OPENED FEB 19, 2003Closed

Unprogrammed other · Complete · Safety · 10 employees at the site · Closed Mar 28, 2003

7310 S. Loop East, Houston, TX 77087 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$875$525Mar 14, 2003Closed
Citation 1, item 1b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Mar 14, 2003Closed
Citation 1, item 2
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Serious$525$315Mar 14, 2003Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2018, the Houston site logged 0 recordable injuries or illnesses among about 21 workers: 0.0 per 100 full-time workers, against a median of 2.8 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Lowery Masonry LLC
Houston · 2018
21 000.02.8

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(1)

(a) Capacity. (1) Except as provided in paragraphs (a)(2), (a)(3), (a)(4), (a)(5) and (g) of this section, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it.

29 CFR 1926.451(a)(4)

(4) Each suspension rope, including connecting hardware, used on adjustable suspension scaffolds shall be capable of supporting, without failure, at least 6 times the maximum intended load applied or transmitted to that rope with the scaffold operating at either the rated load of the hoist, or 2 (minimum) times the stall load of the hoist, whichever is greater.

29 CFR 1926.451(a)(6)

(6) Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

Other masonry contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.