OSHA SearchOSHA records by employer

M a M Construction Inc.: OSHA inspections and violations

Katonah, New York · Roofing Contractors · NAICS 238160

1inspections
6citation items
$15,800current penalties
Jul 16, 2021last inspection

OSHA has inspected M a M Construction Inc. once in New York.

The inspection began on Jul 16, 2021 after a complaint, in Katonah.

That inspection ended with 6 citation items: 6 serious.

Penalties were first proposed at $15,800 and still stand at $15,800.

Scaffolds, general requirements comes up most often in these citations: 4 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and M a M Construction Inc. averages $15,800 (1 cited inspection).

M a M Construction Inc.: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

353employers cited

57 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch M a M Construction Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345423834 OPENED JUL 16, 2021Closed

Complaint · Partial · Safety · 6 employees at the site · Closed Feb 14, 2024

22 Edgemont Rd., Katonah, NY 10536 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$2,341$2,341Aug 11, 2021Final
Citation 1, item 2
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$4,096$4,096Aug 11, 2021Final
Citation 1, item 3
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$2,926$2,926Aug 11, 2021Final
Citation 1, item 4a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$4,096$4,096Aug 11, 2021Final
Citation 1, item 4b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Aug 11, 2021Final
Citation 1, item 5
29 CFR 1926.1053(a)(2) · Ladders in construction
Serious$2,341$2,341Aug 11, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(a)(2)

(2) Ladder rungs, cleats, and steps shall be parallel, level, and uniformly spaced when the ladder is in position for use.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

Other roofing contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.