OSHA SearchOSHA records by employer

M.A.S. Concrete & Layout, Inc.: OSHA inspections and violations

Kissimmee, Florida · Poured Concrete Foundation and Structure Contractors · NAICS 238110

3inspections
5citation items
$6,463current penalties
Jun 28, 2016last inspection

OSHA has inspected M.A.S. Concrete & Layout, Inc. 3 times in Florida since 2005.

The latest one began on Jun 28, 2016 on a referral, in Orlando.

Those inspections ended with 5 citation items: 4 serious and 1 other-than-serious.

Penalties were first proposed at $9,366 and now stand at $6,463, 31% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and M.A.S. Concrete & Layout, Inc. averages $2,245 (1 cited inspection).

M.A.S. Concrete & Layout, Inc.: OSHA citation items per year, 2005 to 2016
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

320employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch M.A.S. Concrete & Layout, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341589810 OPENED JUN 28, 2016Closed

Referral · Complete · Safety · 5 employees at the site · Closed Jan 6, 2017

5374 International Drive, Orlando, FL 32811 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.703(b)(3) · Requirements for cast-in-place concrete
Serious$3,741$2,245Nov 30, 2016Final

Inspection 310363585 OPENED JUL 28, 2006Closed

Planned · Partial · Safety · 14 employees at the site · Closed Sep 21, 2006

3321 Whitestone Circle, Kissimmee, FL 34741 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$3,000$2,250Sep 7, 2006Closed
Citation 1, item 2
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$2,100$1,575Sep 7, 2006Closed

Inspection 308759430 OPENED APR 12, 2005Closed

Planned · Complete · Safety · 6 employees at the site · Closed Jul 20, 2005

Flora Ridge Town Homes,, Kissimmee, FL 34741 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$525$394Jul 7, 2005Closed
Citation 2, item 1
29 CFR 1926.103(d)(1)(iii) · Respiratory protection
Other-than-serious$0$0Jul 7, 2005Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.103 · Respiratory protection

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(1)

(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

29 CFR 1926.701(b)

(b) Reinforcing steel. All protruding reinforcing steel, onto and into which employees could fall, shall be guarded to eliminate the hazard of impalement.

29 CFR 1926.703 · Requirements for cast-in-place concrete

Other poured concrete foundation and structure contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.