M & B Masonry: OSHA inspections and violations

Washington, District of Columbia · Masonry Contractors · NAICS 238140

1inspections
10citation items
$31,671current penalties
Feb 14, 2017last inspection

M & B Masonry has one OSHA inspection on record in District of Columbia.

OSHA opened it on Feb 14, 2017 as a planned inspection, in Washington.

From that inspection OSHA issued 10 citation items: 10 serious.

OSHA proposed $31,671 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (7 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. M & B Masonry averages $31,671 over 1 cited inspection in that time.

M & B Masonry: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

District of Columbia · latest 90 days of OSHA records

14employers cited

Get notified the morning OSHA posts each new citation in District of Columbia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in District of Columbia

Checking a subcontractor, a client or your own company? Watch M & B Masonry and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342155637 OPENED FEB 14, 2017Closed

Planned · Partial · Safety · 7 employees at the site · Closed Mar 14, 2019

3156 City Scrap Dr Ne, Washington, DC 20012 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$4,183$4,183Mar 17, 2017Final
Citation 1, item 2
29 CFR 1926.451(b)(10) · Scaffolds, general requirements
Serious$2,390$2,390Mar 17, 2017Final
Citation 1, item 3
29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements
Serious$4,183$4,183Mar 17, 2017Final
Citation 1, item 4
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$4,183$4,183Mar 17, 2017Final
Citation 1, item 5a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$4,183$4,183Mar 17, 2017Final
Citation 1, item 5b
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Mar 17, 2017Final
Citation 1, item 6
29 CFR 1926.451(g)(1)(vi) · Scaffolds, general requirements
Serious$4,183$4,183Mar 17, 2017Final
Citation 1, item 7
29 CFR 1926.452(c)(4) · Rules for each type of scaffold
Serious$4,183$4,183Mar 17, 2017Final
Citation 1, item 8a
29 CFR 1926.454(a) · Scaffold training
Serious$4,183$4,183Mar 17, 2017Final
Citation 1, item 8b
29 CFR 1926.454(b) · Scaffold training
Serious$0$0Mar 17, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(b)(10)

(10) Scaffold components manufactured by different manufacturers shall not be intermixed unless the components fit together without force and the scaffold's structural integrity is maintained by the user. Scaffold components manufactured by different manufacturers shall not be modified in order to intermix them unless a competent person determines the resulting scaffold is structurally sound.

29 CFR 1926.451(c)(1)(ii)

(ii) Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91 m) wide. The top guy, tie or brace of completed scaffolds shall be placed no further than the 4:1 height from the top. Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other).

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training