OSHA SearchOSHA records by employer

M&M Towing: OSHA inspections and violations

Battle Creek, Michigan · Motor Vehicle Towing · NAICS 488410

1inspections
6citation items
$800current penalties
Jun 12, 2024last inspection

OSHA has inspected M&M Towing once in Michigan.

The inspection began on Jun 12, 2024 after a complaint, in Battle Creek.

That inspection ended with 6 citation items: 2 serious and 4 other-than-serious.

Penalties were first proposed at $800 and still stand at $800.

Electrical wiring methods comes up most often in these citations: 2 items under 1910.305.

How that compares: the median penalty per cited inspection for transportation and warehousing employers since 2015 is $2,415, and M&M Towing averages $800 (1 cited inspection).

M&M Towing: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

665employers cited

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch M&M Towing and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347544553 OPENED JUN 12, 2024Closed

Complaint · Partial · Safety · 7 employees at the site · Closed Oct 16, 2024

850 East Emmett Street, Battle Creek, MI 49014 · Motor Vehicle Towing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.17252(2)
Serious$400$400Jul 15, 2024Final
Citation 1, item 2
29 CFR 1910.28(b)(3)(ii) · Fall protection in general industry
Serious$400$400Jul 15, 2024Final
Citation 2, item 1
29 CFR 408.17232(1)
Other-than-serious$0$0Jul 15, 2024Final
Citation 2, item 2a
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Other-than-serious$0$0Jul 15, 2024Final
Citation 2, item 2b
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$0$0Jul 15, 2024Final
Citation 2, item 3
29 CFR 1910.305(g)(1)(iv) · Electrical wiring methods
Other-than-serious$0$0Jul 15, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.28(b)(3)(ii)

(ii) Each employee is protected from tripping into or stepping into or through any hole that is less than 4 feet (1.2 m) above a lower level by covers or guardrail systems.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(g)(2)(i)

(2) Guarding of live parts. (i) Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means:

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(2)(i)

(2) Covers and canopies. (i) All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

Other motor vehicle towing employers in Michigan

Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.