OSHA SearchOSHA records by employer

M.F. Reynolds, Inc.: OSHA inspections and violations

Boston, Massachusetts · Framing Contractors · NAICS 238130

3inspections
8citation items
$25,086current penalties
Oct 22, 2024last inspection

Since 2010, OSHA inspectors have visited M.F. Reynolds, Inc. in Massachusetts 3 times.

The most recent inspection opened on Oct 22, 2024 on a referral, in Wenham.

In all, OSHA issued 8 citation items: 7 serious and 1 other-than-serious.

The proposed penalties came to $31,849; today they stand at $25,086, 21% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. M.F. Reynolds, Inc. averages $8,731 across 2 cited inspections.

M.F. Reynolds, Inc.: OSHA citation items per year, 2010 to 2024
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

255employers cited

20 of them in the same industry

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch M.F. Reynolds, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347831653 OPENED OCT 22, 2024Closed

Referral · Partial · Safety · 2 employees at the site · Closed Mar 10, 2025

3 Sias Lane, Wenham, MA 01984 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(g)(2) · Scaffolds, general requirements
Serious$11,292$7,904Jan 10, 2025Final
Citation 1, item 1b
29 CFR 1926.454(b) · Scaffold training
Serious$0$0Jan 10, 2025Final

Inspection 345320477 OPENED MAY 20, 2021Closed

Referral · Partial · Safety · 85 employees at the site · Closed Nov 8, 2021

12 Indian Hill Road, Weston, MA 02493 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.304(i)(1) · Woodworking tools
Serious$9,557$9,557Jul 19, 2021Final

Inspection 313796997 OPENED JAN 28, 2010Closed

Referral · Complete · Safety · 28 employees at the site · Closed Mar 25, 2010

7 Commonwealth Ave, Boston, MA 02118 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.304(h) · Woodworking tools
Serious$2,500$1,250Feb 8, 2010Closed
Citation 1, item 2
29 CFR 1926.451(f)(16) · Scaffolds, general requirements
Serious$2,500$1,875Feb 8, 2010Closed
Citation 1, item 3
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$2,500$1,875Feb 8, 2010Closed
Citation 1, item 4
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$3,500$2,625Feb 8, 2010Closed
Citation 2, item 1
29 CFR 1926.150(c)(1)(viii) · Fire protection
Other-than-serious$0$0Feb 8, 2010Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(viii)

(viii) Portable fire extinguishers shall be inspected periodically and maintained in accordance with Maintenance and Use of Portable Fire Extinguishers, NFPA No. 10A-1970.

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.304(i)(1)

(i) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(16)

(16) Platforms shall not deflect more than 1/60 of the span when loaded.

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

Other framing contractors employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.