OSHA SearchOSHA records by employer

M.Q. Sewer & Water Contractors, Inc.: OSHA inspections and violations

Chicago, Illinois · Water and Sewer Line and Related Structures Construction · NAICS 237110

5inspections
5citation items
$2,680current penalties
Oct 16, 2018last inspection

M.Q. Sewer & Water Contractors, Inc. has 5 OSHA inspections on record in Illinois, the first in 1988.

OSHA's last visit started on Oct 16, 2018 as a planned inspection, in Chicago.

Across those inspections OSHA issued 5 citation items: 5 serious.

OSHA proposed $3,800 in penalties. After settlements and reviews the total is $2,680, down 29%.

Most often, OSHA cited 1926.652, trench protection (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. M.Q. Sewer & Water Contractors, Inc. averages $1,680 over 1 cited inspection in that time.

M.Q. Sewer & Water Contractors, Inc.: OSHA citation items per year, 1988 to 2018
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

417employers cited

10 of them in the same industry

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch M.Q. Sewer & Water Contractors, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343536918 OPENED OCT 16, 2018Closed

Planned · Partial · Safety · 5 employees at the site · Closed Oct 26, 2018

6200 S. Major Ave, Chicago, IL 60638 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340743665 OPENED JUN 25, 2015Closed

Planned · Partial · Safety · 5 employees at the site · Closed Oct 13, 2015

5619 S Lafayette Ave, Chicago, IL 60621 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.652(g)(1)(iii) · Trench protection
Serious$2,800$1,680Sep 21, 2015Final

Inspection 313238065 OPENED MAY 12, 2009Closed

Planned · Partial · Safety · 30 employees at the site · Closed Jun 4, 2009

School St. Alley Btw Cambell St. & Algonquin Ave, Des Plaines, IL 60018 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 103067021 OPENED JUN 30, 1990Closed

Referral · Partial · Safety · 2 employees at the site · Closed Aug 8, 1990

Bryn Mawr Avenue West Of Cumberland Avenue, Chicago, IL 60631 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.652(a)(1) · Trench protection
Serious$1,000$1,000Jul 12, 1990Closed
Citation 1, item 1b
29 CFR 1926.652(c) · Trench protection
Serious$0$0Jul 12, 1990Closed
Citation 1, item 1c
29 CFR 1926.652(e)(1)(ii) · Trench protection
Serious$0$0Jul 12, 1990Closed
Citation 1, item 1d
29 CFR 1926.651(k)(1) · Excavations
Serious$0$0Jul 12, 1990Closed

Inspection 103263117 OPENED JUL 25, 1988Closed

Referral · Complete · Safety · 6 employees at the site · Closed Jul 25, 1988

1800 - 1830 West Fullerton Avenue, Chicago, IL 60614 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

29 CFR 1926.652 · Trench protection

29 CFR 1926.652(a)(1)

(a) Protection of employees in excavations. (1) Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when:

29 CFR 1926.652(c)

(c) Design of support systems, shield systems, and other protective systems. Designs of support systems shield systems, and other protective systems shall be selected and constructed by the employer or his designee and shall be in accordance with the requirements of paragraph (c)(1); or, in the alternative, paragraph (c)(2); or, in the alternative, paragraph (c)(3); or, in the alternative, paragraph (c)(4) as follows:

Other water and sewer line and related structures construction employers in Illinois

Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.