OSHA SearchOSHA records by employer

M.S. Construction LLC: OSHA inspections and violations

Mustang, Oklahoma · Framing Contractors · NAICS 238130

5inspections
10citation items
$6,544current penalties
Apr 9, 2026last inspection

OSHA has inspected M.S. Construction LLC 5 times in Oklahoma since 1985.

The latest one began on Apr 9, 2026 to follow up on an earlier case, in Mustang.

Those inspections ended with 10 citation items: 8 serious and 2 other-than-serious.

Penalties were first proposed at $10,800 and now stand at $6,544, 39% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 4 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and M.S. Construction LLC averages $3,192 (2 cited inspections).

M.S. Construction LLC: OSHA citation items per year, 1985 to 2026
Citation items per year, by inspection date.

Oklahoma · latest 90 days of OSHA records

58employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Oklahoma: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oklahoma

Checking a subcontractor, a client or your own company? Watch M.S. Construction LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348879305 OPENED APR 9, 2026Closed

Follow-up · Partial · Safety · 5 employees at the site · Closed Apr 17, 2026

11621 Sw 58th St, Mustang, OK 73064 · Framing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 348879388 OPENED APR 9, 2026Closed

Follow-up · Partial · Safety · 5 employees at the site · Closed Apr 17, 2026

11701 Sw 58th St, Mustang, OK 73064 · Framing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 348145772 OPENED MAR 31, 2025Closed

Planned · Partial · Safety · 5 employees at the site · Closed Apr 17, 2026

11621 Sw 58th St, Mustang, OK 73064 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$3,547$2,128Sep 18, 2025Final
Citation 1, item 1b
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$0$0Sep 18, 2025Final
Citation 1, item 2a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,128$1,277Sep 18, 2025Final
Citation 1, item 2b
29 CFR 1926.1053(b)(18) · Ladders in construction
Serious$0$0Sep 18, 2025Final

Inspection 348146085 OPENED MAR 31, 2025Closed

Planned · Partial · Safety · 5 employees at the site · Closed Apr 17, 2026

11701 Sw 58th St, Mustang, OK 73064 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,837$1,702Sep 18, 2025Final
Citation 1, item 1b
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$0$0Sep 18, 2025Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,128$1,277Sep 18, 2025Final

Inspection 2096113 OPENED MAR 28, 1985Closed

Planned · Complete · Safety · 2 employees at the site · Closed Oct 1, 1987

1920 E 2nd St, Edmond, OK 73034 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.500(d)(1) · Scope, application, and definitions applicable to this subpart
Serious$160$160May 16, 1985Closed
Citation 2, item 1
29 CFR 1926.450(a)(10) · Scope, application and definitions applicable to this subpart
Other-than-serious$0$0May 16, 1985Closed
Citation 2, item 2
29 CFR 1926.450(b)(12) · Scope, application and definitions applicable to this subpart
Other-than-serious$0$0May 16, 1985Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(18)

(18) Ladder repairs shall restore the ladder to a condition meeting its original design criteria, before the ladder is returned to use.

29 CFR 1926.450 · Scope, application and definitions applicable to this subpart

29 CFR 1926.450(a)(10)

(a) Scope and application. This subpart applies to all scaffolds used in workplaces covered by this part. It does not apply to crane or derrick suspended personnel platforms. The criteria for aerial lifts are set out exclusively in § 1926.453.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.500 · Scope, application, and definitions applicable to this subpart

29 CFR 1926.501 · Fall protection in construction

Other framing contractors employers in Oklahoma

Alert subscribers get notified of each newly cited employer in Oklahoma the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.