OSHA SearchOSHA records by employer

M.T.M. Contractors, Inc.: OSHA inspections and violations

Pinellas Park, Florida · Water and Sewer Line and Related Structures Construction · NAICS 237110

5inspections
3citation items
$12,892current penalties
May 20, 2024last inspection

M.T.M. Contractors, Inc. has 5 OSHA inspections on record in Florida, the first in 1992.

OSHA's last visit started on May 20, 2024 after a complaint, in Saint Petersburg.

Across those inspections OSHA issued 3 citation items: 1 serious and 2 other-than-serious.

OSHA proposed $14,117 in penalties. After settlements and reviews the total is $12,892, down 9%.

Most often, OSHA cited 1926.651, excavations (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. M.T.M. Contractors, Inc. averages $9,217 over 1 cited inspection in that time.

M.T.M. Contractors, Inc.: OSHA citation items per year, 1992 to 2024
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

319employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch M.T.M. Contractors, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347492290 OPENED MAY 20, 2024Closed

Complaint · Partial · Safety · 6 employees at the site · Closed Sep 10, 2024

2597 62nd St. N, Saint Petersburg, FL 33710 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(k)(1) · Excavations
Other-than-serious$6,452$6,452Jun 18, 2024Final
Citation 1, item 2
29 CFR 1926.651(c)(2) · Excavations
Other-than-serious$2,765$2,765Jun 18, 2024Final

Inspection 339052722 OPENED MAY 8, 2013Closed

Planned · Complete · Safety · 4 employees at the site · Closed May 13, 2013

502 Creekview Court (mckay Creek Runs Behind), Belleair Bluffs, FL 33770 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 316306646 OPENED JAN 13, 2012Closed

Planned · Partial · Safety · 7 employees at the site · Closed Feb 8, 2012

Behind 7315 U.s. Hwy 19 N., Pinellas Park, FL 33781 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.652(a)(1) · Trench protection
Serious$4,900$3,675Jan 31, 2012Closed

Inspection 106499502 OPENED SEP 22, 1992Closed

Unprogrammed related · Complete · Safety · 5 employees at the site · Closed Sep 25, 1992

7001 Park Blvd., Pinellas Park, FL 34665 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 109719120 OPENED JUN 18, 1992Closed

Planned · Complete · Safety · 3 employees at the site · Closed Jun 18, 1992

16200 49th St N, Clearwater, FL 34622 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

29 CFR 1926.652 · Trench protection

29 CFR 1926.652(a)(1)

(a) Protection of employees in excavations. (1) Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when:

Other water and sewer line and related structures construction employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.