OSHA SearchOSHA records by employer

Macaljon/SCL, Inc.: OSHA inspections and violations

Savannah, Georgia · Roofing Contractors · NAICS 238160

7inspections
15citation items
$22,082current penalties
Sep 30, 2024last inspection

OSHA has inspected Macaljon/SCL, Inc. 7 times in Georgia since 2000.

The latest one began on Sep 30, 2024 on a referral, in Savannah.

Those inspections ended with 15 citation items: 13 serious and 2 other-than-serious.

Penalties were first proposed at $23,957 and now stand at $22,082, 8% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 6 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Macaljon/SCL, Inc. averages $9,457 (1 cited inspection).

Macaljon/SCL, Inc. also files yearly injury logs with OSHA, summarized below.

It reported 2 severe injuries to OSHA since 2015.

Macaljon/SCL, Inc.: OSHA citation items per year, 2000 to 2024
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

142employers cited

11 of them in the same industry

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Macaljon/SCL, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347783854 OPENED SEP 30, 2024Closed

Referral · Partial · Safety · 4 employees at the site · Closed Mar 19, 2025

1 Brampton Rd., Savannah, GA 31408 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.502(d)(16)(iii) · Fall protection systems
Serious$9,457$9,457Feb 20, 2025Final

Inspection 342806544 OPENED NOV 29, 2017Closed

Fatality or catastrophe · No inspection · Health · 3 employees at the site · Closed Mar 1, 2018

1200 Lathrop Road, Savannah, GA 31405 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 314096124 OPENED OCT 24, 2011Closed

Referral · Partial · Safety · 26 employees at the site · Closed Jan 4, 2012

1 Bonnybridge Rd, Port Wentworth, GA 31407 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(a)(2) · Fall protection in construction
Serious$7,000$7,000Dec 20, 2011Closed

Inspection 314089053 OPENED MAY 18, 2010Closed

Referral · Partial · Safety · 10 employees at the site · Closed Sep 9, 2010

1 Bonnybridge Rd., Port Wentworth, GA 31407 · Other Heavy and Civil Engineering Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(d) · Electrical wiring methods
Serious$1,125$844Aug 20, 2010Closed
Citation 1, item 2
29 CFR 1926.1052(c)(1)(ii) · Stairways in construction
Serious$900$675Aug 20, 2010Closed
Citation 2, item 1
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Aug 20, 2010Closed

Inspection 303775191 OPENED NOV 4, 2003Closed

Referral · Complete · Safety · 5 employees at the site · Closed Feb 25, 2004

3000 Louisville Rd, Savannah, GA 31415 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.352(e) · Fire prevention
Serious$1,100$825Jan 29, 2004Closed
Citation 2, item 1
29 CFR 1926.850(a) · Preparatory operations
Other-than-serious$0$0Jan 29, 2004Closed

Inspection 300652740 OPENED MAY 5, 2000Closed

Unprogrammed related · Partial · Safety · 54 employees at the site · Closed Oct 24, 2000

1 Kerr-mcgee Road, Savannah, GA 31404 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$875$656Sep 29, 2000Closed
Citation 1, item 1b
29 CFR 1926.451(b)(4) · Scaffolds, general requirements
Serious$0$0Sep 29, 2000Closed
Citation 1, item 1c
29 CFR 1926.451(b)(7) · Scaffolds, general requirements
Serious$0$0Sep 29, 2000Closed
Citation 1, item 2a
29 CFR 1926.451(f)(4) · Scaffolds, general requirements
Serious$875$656Sep 29, 2000Closed
Citation 1, item 2b
29 CFR 1926.451(f)(15)(ii) · Scaffolds, general requirements
Serious$0$0Sep 29, 2000Closed
Citation 1, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$875$656Sep 29, 2000Closed
Citation 1, item 4
29 CFR 1926.452(b)(6) · Rules for each type of scaffold
Serious$875$656Sep 29, 2000Closed

Inspection 300652849 OPENED MAY 5, 2000Closed

Unprogrammed related · Partial · Health · 54 employees at the site · Closed Oct 24, 2000

1 Kerr-mcgee Road, Savannah, GA 31404 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.119(k)(2) · Process safety management
Serious$875$656Sep 29, 2000Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2024, the Savannah site logged 1 recordable injury or illness among about 325 workers: 0.3 per 100 full-time workers, against a median of 1.8 for its industry. Those cases cost 95 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
MacAljon SCL
Savannah · 2024
325 110.31.8
Main Office
Savannah · 2023
423 301.22.8
MacAljon
Savannah · 2016
358 210.71.8

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.

Sep 28, 2024, Savannah: Hospitalization · fractures · head and extremities

An employee was on a roof repairing a skylight when they fell through the skylight to the concrete floor. The employee sustained fractures to both legs, both elbows, a shoulder, a cheekbone, and their nose.

Apr 13, 2015, Savannah: Hospitalization · heat (thermal) burns, unspecified · nonclassifiable

An employee was burned by hot steam/water when he was removing a flange off an unused condensation line.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.119 · Process safety management

29 CFR 1910.119(k)(2)

(2) The permit shall document that the fire prevention and protection requirements in 29 CFR 1910.252(a) have been implemented prior to beginning the hot work operations; it shall indicate the date(s) authorized for hot work; and identify the object on which hot work is to be performed. The permit shall be kept on file until completion of the hot work operations.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)(ii)

(ii) One stairrail system along each unprotected side or edge.

29 CFR 1926.352 · Fire prevention

29 CFR 1926.352(e)

(e) When the welding, cutting, or heating operation is such that normal fire prevention precautions are not sufficient, additional personnel shall be assigned to guard against fire while the actual welding, cutting, or heating operation is being performed, and for a sufficient period of time after completion of the work to ensure that no possibility of fire exists. Such personnel shall be instructed as to the specific anticipated fire hazards and how the firefighting equipment provided is to be used.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.850 · Preparatory operations

Other roofing contractors employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.