Inspection 347079303 OPENED NOV 2, 2023Closed
23400 Haggerty Road, Farmington Hills, MI 48335 · Precision Turned Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 2013, OSHA inspectors have visited Maclean Fogg Component Solutions in Michigan 6 times.
The most recent inspection opened on Nov 2, 2023 after a complaint, in Farmington Hills.
In all, OSHA issued 30 citation items: 12 serious, 1 repeat and 17 other-than-serious.
The proposed penalties came to $35,950; today they stand at $17,555, 51% less.
The rule cited most here is 1910.305 (electrical wiring methods), 3 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Maclean Fogg Component Solutions averages $4,067 across 3 cited inspections.
Michigan · latest 90 days of OSHA records
665employers cited
Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Michigan
Checking a subcontractor, a client or your own company? Watch Maclean Fogg Component Solutions and get notified the morning OSHA posts a new citation for it.
Watch this company23400 Haggerty Road, Farmington Hills, MI 48335 · Precision Turned Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
3200 W 14 Mile Rd, Royal Oak, MI 48073 · Bolt, Nut, Screw, Rivet, and Washer Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Nov 8, 2020: Employee suffers fingertip amputation while clearing jam fro
At 11:15 a.m. on November 8, 2020, an employee opened the guard on the right side of the MAS-20 Tapper Machine #75 to locate a jammed part. The employee reached into the machine without performing lockout, and the unexpected motion of the machine pinched his right index fingertip between the lock block and closing pin, causing an amputation of the right index fingertip. The employee was treated without hospitalization.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 408.12618(1) |
Serious | $7,000 | $3,500 | Apr 9, 2021 | Final |
3200 W 14 Mile Rd, Royal Oak, MI 48073 · Bolt, Nut, Screw, Rivet, and Washer Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Jan 9, 2021: Employee amputates finger when machine cycles
At 12:40 p.m. on January 9, 2021, an employee was clearing a jammed part from the MAS-20 tapper machine that was not locked out. The machine cycled, pinching the employee's finger between the lock block and closing pin (pinch point). The employee's finger was amputated. The employee was treated without hospitalization.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 408.12618(1) |
Serious | $7,000 | $3,500 | Mar 4, 2021 | Final |
50855 E Russell Schmidt Blvd, Chesterfield, MI 48051 · Bolt, Nut, Screw, Rivet, and Washer Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 408.11421(4) |
Serious | $2,400 | $1,200 | Apr 27, 2017 | Final |
| Citation 2, item 1 29 CFR 408.10034(9) |
Repeat | $8,000 | $4,000 | Apr 27, 2017 | Final |
| Citation 3, item 1 29 CFR 408.12635(1)(A) |
Other-than-serious | $0 | $0 | Apr 27, 2017 | Final |
| Citation 3, item 2 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Apr 27, 2017 | Final |
| Citation 3, item 3 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Other-than-serious | $0 | $0 | Apr 27, 2017 | Final |
50855 E Russell Schmidt Blvd, Chesterfield, MI 48051 · Bolt, Nut, Screw, Rivet, and Washer Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 408.10034(9) |
Serious | $1,400 | $700 | Jan 14, 2015 | Final |
| Citation 1, item 2a 29 CFR 408.10213(2) |
Serious | $1,750 | $875 | Jan 14, 2015 | Final |
| Citation 1, item 2b 29 CFR 408.10220(1) |
Serious | $0 | $0 | Jan 14, 2015 | Final |
| Citation 1, item 3 29 CFR 408.10727(1) |
Serious | $1,400 | $700 | Jan 14, 2015 | Final |
| Citation 1, item 4 29 CFR 408.10731(1) |
Serious | $1,400 | $700 | Jan 14, 2015 | Final |
| Citation 1, item 5 29 CFR 408.12638(2) |
Serious | $1,400 | $700 | Jan 14, 2015 | Final |
| Citation 1, item 6 29 CFR 408.12638(5) |
Serious | $1,050 | $420 | Jan 14, 2015 | Final |
| Citation 1, item 7 29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements |
Serious | $1,400 | $560 | Jan 14, 2015 | Final |
| Citation 2, item 1a 29 CFR 408.10033(1) |
Other-than-serious | $0 | $0 | Jan 14, 2015 | Final |
| Citation 2, item 1b 29 CFR 408.10033(2) |
Other-than-serious | $0 | $0 | Jan 14, 2015 | Final |
| Citation 2, item 2 29 CFR 408.10187(1) |
Other-than-serious | $0 | $0 | Jan 14, 2015 | Final |
| Citation 2, item 3 29 CFR 408.11223(1) |
Other-than-serious | $0 | $0 | Jan 14, 2015 | Final |
| Citation 2, item 4a 29 CFR 408.13308(3) |
Other-than-serious | $0 | $0 | Jan 14, 2015 | Final |
| Citation 2, item 4b 29 CFR 408.13393(3) |
Other-than-serious | $0 | $0 | Jan 14, 2015 | Final |
| Citation 2, item 5 29 CFR 408.13861(1) |
Other-than-serious | $0 | $0 | Jan 14, 2015 | Final |
| Citation 2, item 6a 29 CFR 1910.303(g)(2)(ii) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Jan 14, 2015 | Final |
| Citation 2, item 6b 29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Jan 14, 2015 | Final |
| Citation 2, item 6c 29 CFR 1910.305(b)(2)(i) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Jan 14, 2015 | Final |
| Citation 2, item 6d 29 CFR 1910.305(g)(1)(iv) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Jan 14, 2015 | Final |
| Citation 2, item 6e 29 CFR 408.14007(7) |
Other-than-serious | $0 | $0 | Jan 14, 2015 | Final |
| Citation 2, item 7 29 CFR 408.14965(1) |
Other-than-serious | $0 | $0 | Jan 14, 2015 | Final |
| Citation 2, item 8 29 CFR 1910.1200(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Jan 14, 2015 | Final |
3200 W 14 Mile Rd, Royal Oak, MI 48073 · Bolt, Nut, Screw, Rivet, and Washer Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $1,750 | $700 | Oct 4, 2013 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.1200(e)(1)
(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:
29 CFR 1910.147(c)(4)(i)
(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.
29 CFR 1910.147(c)(6)(i)
(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.
Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.