OSHA SearchOSHA records by employer

Mak Lead Incorporated: OSHA inspections and violations

Anchorage, Alaska · Framing Contractors · NAICS 238130

1inspections
3citation items
$1,260current penalties
Jun 21, 2016last inspection

Mak Lead Incorporated has one OSHA inspection on record in Alaska.

OSHA opened it on Jun 21, 2016 on a referral, in Anchorage.

From that inspection OSHA issued 3 citation items: 2 serious and 1 other-than-serious.

OSHA proposed $1,800 in penalties. After settlements and reviews the total is $1,260, down 30%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Mak Lead Incorporated averages $1,260 over 1 cited inspection in that time.

Mak Lead Incorporated: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Alaska · latest 90 days of OSHA records

37employers cited

Get notified the morning OSHA posts each new citation in Alaska: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Alaska

Checking a subcontractor, a client or your own company? Watch Mak Lead Incorporated and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341564920 OPENED JUN 21, 2016Closed

Referral · Partial · Safety · 4 employees at the site · Closed Sep 2, 2016

L26 B3a Whitby Cir., Anchorage, AK 99515 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,000$700Jul 12, 2016Final
Citation 1, item 2
29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites
Serious$800$560Jul 12, 2016Final
Citation 2, item 1
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0Jul 12, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(i)(2)(i)

(2) Guarding of live parts. (i) Except as required or permitted elsewhere in this subpart, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by cabinets or other forms of enclosures, or by any of the following means:

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.503(b)(1)

(b) Certification of training. (1) The employer shall verify compliance with paragraph (a) of this section by preparing a written certification record. The written certification record shall contain the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. If the employer relies on training conducted by another employer or completed prior to the effective date of this section, the certification record shall indicate the date the employer determined the prior training was adequate rather than the date of actual training.

Other framing contractors employers in Alaska

Alert subscribers get notified of each newly cited employer in Alaska the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.