OSHA SearchOSHA records by employer

Mallano Construction Corp.: OSHA inspections and violations

Mount Vernon, New York · Residential Remodelers · NAICS 236118

1inspections
4citation items
$6,800current penalties
Jul 11, 2016last inspection

OSHA inspectors have visited Mallano Construction Corp. in New York one time.

It opened on Jul 11, 2016 on a referral, in Mount Vernon.

In all, OSHA issued 4 citation items: 4 serious.

The penalties, $6,800 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Mallano Construction Corp. averages $6,800 across 1 cited inspection.

Mallano Construction Corp.: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

353employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Mallano Construction Corp. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341631950 OPENED JUL 11, 2016Closed

Referral · Partial · Safety · 3 employees at the site · Closed Jul 25, 2019

40 North St., Mount Vernon, NY 10550 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(5)(i) · Scaffolds, general requirements
Serious$2,000$2,000Jul 28, 2016Final
Citation 1, item 2a
29 CFR 1926.451(f)(6) · Scaffolds, general requirements
Serious$2,800$2,800Jul 28, 2016Final
Citation 1, item 2b
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Jul 28, 2016Final
Citation 1, item 3
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$2,000$2,000Jul 28, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(5)(i)

(5)(i) Each end of a platform 10 feet or less in length shall not extend over its support more than 12 inches (30 cm) unless the platform is designed and installed so that the cantilevered portion of the platform is able to support employees and/or materials without tipping, or has guardrails which block employee access to the cantilevered end.

29 CFR 1926.451(f)(6)

(6) The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows:

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(j)(2)

(2) Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.

29 CFR 1926.454 · Scaffold training

Other residential remodelers employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.