OSHA SearchOSHA records by employer

Mallick Plumbing & Heating, Inc.: OSHA inspections and violations

Silver Spring, Maryland · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

5inspections
14citation items
$788current penalties
Apr 10, 2018last inspection

Mallick Plumbing & Heating, Inc. has 5 OSHA inspections on record in Maryland, the first in 2007.

OSHA's last visit started on Apr 10, 2018 after an accident, in Silver Spring.

Across those inspections OSHA issued 14 citation items: 14 other-than-serious.

OSHA proposed $1,125 in penalties. After settlements and reviews the total is $788, down 30%.

Most often, OSHA cited 1910.146, permit-required confined spaces (6 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Mallick Plumbing & Heating, Inc. averages $788 over 1 cited inspection in that time.

Mallick Plumbing & Heating, Inc.: OSHA citation items per year, 2007 to 2018
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

183employers cited

9 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Mallick Plumbing & Heating, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343087839 OPENED APR 10, 2018Closed

Accident · Partial · Health · 3 employees at the site · Closed Dec 6, 2018

8710 Brookville Road, Silver Spring, MD 20910 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Incident on Apr 10, 2018: Employee in pump pit is overwhelmed by diesel fuel vapors

At 11:15 a.m. on April 10, 2018, Employee #1, a master plumber, and a coworker who was Employee #1's apprentice, both employed by a plumbing company, were installing a new dewatering pump unit in a pit. Between 7:30 a.m. and 11:15 a.m., Employee #1 entered the pit three times, each time wearing fall protection and personal protective equipment. His coworker was stationed at the pit's entrance. During his third stint working in the pit, after 30 to 40 minutes, Employee #1 was overwhelmed by vapors. His coworker used Employee #1's attached lifeline to rescue him. Both employees later reported that they had been smelling diesel fuel all morning. Employee #1 was transported to the hospital, admitted, and treated for his exposure.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.146(c)(1) · Permit-required confined spaces
Other-than-serious$1,125$788Jun 28, 2018Final
Citation 1, item 1c
29 CFR 1910.146(d)(5)(i) · Permit-required confined spaces
Other-than-serious$0$0Jun 28, 2018Final
Citation 1, item 1d
29 CFR 1910.146(e)(1) · Permit-required confined spaces
Other-than-serious$0$0Jun 28, 2018Final
Citation 1, item 1f
29 CFR 1910.146(i) · Permit-required confined spaces
Other-than-serious$0$0Jun 28, 2018Final
Citation 1, item 1g
29 CFR 1910.146(j) · Permit-required confined spaces
Other-than-serious$0$0Jun 28, 2018Final
Citation 1, item 1h
29 CFR 1910.146(k)(2)(iii) · Permit-required confined spaces
Other-than-serious$0$0Jun 28, 2018Final

Inspection 316588094 OPENED SEP 5, 2012Closed

Planned · Complete · Safety · 1 employee at the site · Closed Feb 8, 2013

210 Shorebird Street, Frederick, MD 21701 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(7)(ii) · Fall protection in construction
Other-than-serious$0$0Oct 22, 2012Closed
Citation 1, item 2
29 CFR 50408 A01
Other-than-serious$0$0Oct 22, 2012Closed

Inspection 315572644 OPENED MAY 10, 2011Closed

Planned · Complete · Safety · 7 employees at the site · Closed Jul 14, 2011

5000 Bradley Boulevard, Bethesda, MD 20815 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Other-than-serious$0$0Jun 22, 2011Closed
Citation 1, item 2
29 CFR 50405 B03
Other-than-serious$0$0Jun 22, 2011Closed
Citation 1, item 3
29 CFR 50406 A01
Other-than-serious$0$0Jun 22, 2011Closed
Citation 1, item 4
29 CFR 50408 A01
Other-than-serious$0$0Jun 22, 2011Closed

Inspection 314897638 OPENED AUG 30, 2010Closed

Planned · Complete · Safety · 2 employees at the site · Closed Aug 30, 2010

13407 Lydia Street, Silver Spring, MD 20906 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311748180 OPENED DEC 5, 2007Closed

Planned · Complete · Safety · 3 employees at the site · Closed Jan 14, 2008

28539 Marlboro Avenue, Easton, MD 21601 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 50405 B01
Other-than-serious$0$0Dec 11, 2007Closed
Citation 1, item 2
29 CFR 50406 A01
Other-than-serious$0$0Dec 11, 2007Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.146(c)(1)

(c) General requirements. (1) The employer shall evaluate the workplace to determine if any spaces are permit- required confined spaces.

29 CFR 1910.146(d)(5)(i)

(i) Test conditions in the permit space to determine if acceptable entry conditions exist before entry is authorized to begin, except that, if isolation of the space is infeasible because the space is large or is part of a continuous system (such as a sewer), pre-entry testing shall be performed to the extent feasible before entry is authorized and, if entry is authorized, entry conditions shall be continuously monitored in the areas where authorized entrants are working;

29 CFR 1910.146(e)(1)

(e) Permit system. (1) Before entry is authorized, the employer shall document the completion of measures required by paragraph (d)(3) of this section by preparing an entry permit.

29 CFR 1926.501 · Fall protection in construction

Other plumbing, heating, and air-conditioning contractors employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.