OSHA SearchOSHA records by employer

Mamota Stone, LLC: OSHA inspections and violations

Middletown, Delaware · Other Building Finishing Contractors · NAICS 238390

1inspections
3citation items
$3,000current penalties
Feb 7, 2024last inspection

OSHA has inspected Mamota Stone, LLC once in Delaware.

The inspection began on Feb 7, 2024, in Middletown.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $4,148 and now stand at $3,000, 28% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Mamota Stone, LLC averages $3,000 (1 cited inspection).

Mamota Stone, LLC: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Delaware · latest 90 days of OSHA records

30employers cited

Get notified the morning OSHA posts each new citation in Delaware: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Delaware

Checking a subcontractor, a client or your own company? Watch Mamota Stone, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347265704 OPENED FEB 7, 2024Closed

Unprogrammed other · Partial · Safety · 3 employees at the site · Closed Mar 30, 2026

Lot #16 Andrew Court At Middletown Reserve, Middletown, DE 19709 · Other Building Finishing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2a
29 CFR 1926.451(b)(3) · Scaffolds, general requirements
Serious$4,148$3,000Aug 1, 2024Final
Citation 1, item 2b
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Serious$0$0Aug 1, 2024Final
Citation 1, item 2c
29 CFR 1926.451(h)(1) · Scaffolds, general requirements
Serious$0$0Aug 1, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(3)

(3) Except as provided in paragraphs (b)(3) (i) and (ii) of this section, the front edge of all platforms shall not be more than 14 inches (36 cm) from the face of the work, unless guardrail systems are erected along the front edge and/or personal fall arrest systems are used in accordance with paragraph (g) of this section to protect employees from falling.

29 CFR 1926.451(c)(1)

(c) Criteria for supported scaffolds. (1) Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means, as follows:

29 CFR 1926.451(h)(1)

(h) Falling object protection. (1) In addition to wearing hardhats each employee on a scaffold shall be provided with additional protection from falling hand tools, debris, and other small objects through the installation of toeboards, screens, or guardrail systems, or through the erection of debris nets, catch platforms, or canopy structures that contain or deflect the falling objects. When the falling objects are too large, heavy or massive to be contained or deflected by any of the above-listed measures, the employer shall place such potential falling objects away from the edge of the surface from which they could fall and shall secure those materials as necessary to prevent their falling.

Other other building finishing contractors employers in Delaware

Alert subscribers get notified of each newly cited employer in Delaware the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.