OSHA SearchOSHA records by employer

Manao Construction LLC: OSHA inspections and violations

Honolulu, Hawaii · All Other Specialty Trade Contractors · NAICS 238990

6inspections
5citation items
$8,408current penalties
Apr 10, 2025last inspection

OSHA has inspected Manao Construction LLC 6 times in Hawaii since 2016.

The latest one began on Apr 10, 2025 on a referral, in Honolulu.

Those inspections ended with 5 citation items: 3 serious and 2 other-than-serious.

Penalties were first proposed at $12,012 and now stand at $8,408, 30% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Manao Construction LLC averages $4,204 (2 cited inspections).

Manao Construction LLC: OSHA citation items per year, 2016 to 2025
Citation items per year, by inspection date.

Hawaii · latest 90 days of OSHA records

64employers cited

Get notified the morning OSHA posts each new citation in Hawaii: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Hawaii

Checking a subcontractor, a client or your own company? Watch Manao Construction LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348174673 OPENED APR 10, 2025Closed

Referral · Partial · Safety · 9 employees at the site · Closed May 6, 2025

1800 Kalakaua Ave., Honolulu, HI 96815 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$4,256$2,979Apr 24, 2025Final
Citation 1, item 2
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$4,256$2,979Apr 24, 2025Final
Citation 2, item 1
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0Apr 24, 2025Final

Inspection 346770969 OPENED JUN 13, 2023Closed

Complaint · Partial · Health · 3 employees at the site · Closed Jun 21, 2023

98-1254 Ka?ahumanu St, Pearl City, HI 96782 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343423919 OPENED AUG 29, 2018Closed

Planned · Complete · Health · 6 employees at the site · Closed Sep 4, 2018

98-1005 Moanalua Road, Aiea, HI 96701 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343427407 OPENED AUG 10, 2018Closed

Planned · Complete · Health · 6 employees at the site · Closed Sep 4, 2018

1040 Sand Island Parkway #100, Honolulu, HI 96819 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342545928 OPENED AUG 10, 2017Closed

Unprogrammed other · Complete · Safety · 11 employees at the site · Closed Aug 14, 2017

1801 Kalakaua Avenue, Honolulu, HI 96814 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341774131 OPENED SEP 13, 2016Closed

Planned · Complete · Safety · 40 employees at the site · Closed Oct 26, 2016

1040 Sand Island Pkwy #100, Honolulu, HI 96819 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$3,500$2,450Oct 5, 2016Final
Citation 2, item 1
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Other-than-serious$0$0Oct 5, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.304(g)(5)

(5) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(2)(i)

(2) Covers and canopies. (i) All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other all other specialty trade contractors employers in Hawaii

Alert subscribers get notified of each newly cited employer in Hawaii the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.