OSHA SearchOSHA records by employer

Mann and Hummel: OSHA inspections and violations

Wichita Falls, Texas · Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing · NAICS 333413

1inspections
3citation items
$13,221current penalties
Mar 27, 2024last inspection

Mann and Hummel has one OSHA inspection on record in Texas.

OSHA opened it on Mar 27, 2024 after a complaint, in Wichita Falls.

From that inspection OSHA issued 3 citation items: 2 serious and 1 other-than-serious.

OSHA proposed $22,035 in penalties. After settlements and reviews the total is $13,221, down 40%.

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Mann and Hummel averages $13,221 over 1 cited inspection in that time.

Mann and Hummel: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

394employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Mann and Hummel and get notified the morning OSHA posts a new citation for it.

Watch this company

Company-wide record

OSHA records show Mann and Hummel at 2 sites in 2 states. Together they've had 3 inspections and $28,821 in current penalties.

We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.

Included with any plan: the site-by-site record for all 2 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.

See plans

Inspection history

Inspection 347376287 OPENED MAR 27, 2024Closed

Complaint · Partial · Safety · 418 employees at the site · Closed Aug 23, 2024

2801 Production Blvd, Wichita Falls, TX 76302 · Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(b)(4) · Exit routes
Serious$13,828$8,297Jun 24, 2024Final
Citation 1, item 2
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Serious$6,913$4,148Jun 24, 2024Final
Citation 2, item 1
29 CFR 1910.303(g)(1)(i) · Electrical equipment, general requirements
Other-than-serious$1,294$776Jun 24, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(c)(1)

(c) General requirements. (1) The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(g)(1)(i)

(i) Working space for equipment likely to require examination, adjustment, servicing, or maintenance while energized shall comply with the following dimensions, except as required or permitted elsewhere in this subpart:

29 CFR 1910.37 · Exit routes

29 CFR 1910.37(b)(4)

(4) If the direction of travel to the exit or exit discharge is not immediately apparent, signs must be posted along the exit access indicating the direction of travel to the nearest exit and exit discharge. Additionally, the line-of-sight to an exit sign must clearly be visible at all times.

Other industrial and commercial fan and blower and air purification equipment manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.