OSHA SearchOSHA records by employer

Manuel Molino: OSHA inspections and violations

South Lake, Texas · Roofing, Siding, and Insulation Material Merchant Wholesalers · NAICS 423330

1inspections
5citation items
$6,800current penalties
Oct 27, 2015last inspection

OSHA inspectors have visited Manuel Molino in Texas one time.

It opened on Oct 27, 2015 as a planned inspection, in South Lake.

In all, OSHA issued 5 citation items: 5 serious.

The penalties, $6,800 in total, stand where OSHA first set them.

The rule cited most here is 1926.405 (job-site wiring), 2 times.

Among wholesale employers, the typical cited inspection since 2015 ends with a $3,425 penalty. Manuel Molino averages $6,800 across 1 cited inspection.

Manuel Molino: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Want to know if OSHA cites Manuel Molino again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341015667 OPENED OCT 27, 2015Closed

Planned · Partial · Safety · 4 employees at the site · Closed Oct 5, 2017

3071 W. Southlake Blvd., South Lake, TX 76092 · Roofing, Siding, and Insulation Material Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(a)(2)(ii)(i) · Job-site wiring
Serious$1,200$1,200Dec 4, 2015Final
Citation 1, item 2a
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$1,200$1,200Dec 4, 2015Final
Citation 1, item 2b
29 CFR 1926.416(e)(1) · Electrical safety in construction
Serious$0$0Dec 4, 2015Final
Citation 1, item 3
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$2,800$2,800Dec 4, 2015Final
Citation 1, item 4
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$1,600$1,600Dec 4, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(a)(2)(ii)(i)

(iii) Guarding. For temporary wiring over 600 volts, nominal, fencing, barriers, or other effective means shall be provided to prevent access of other than authorized and qualified personnel.

29 CFR 1926.405(g)(2)(iv)

(iv) Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.501 · Fall protection in construction