Marathon Galveston Bay Refinery: OSHA inspections and violations

Texas City, Texas · Petroleum Refineries · NAICS 324110

3inspections
5citation items
$51,970current penalties
May 16, 2022last inspection

OSHA has inspected Marathon Galveston Bay Refinery 3 times in Texas since 2017.

The latest one began on May 16, 2022 after a complaint, in Texas City.

Those inspections ended with 5 citation items: 2 serious and 3 other-than-serious.

Penalties were first proposed at $58,720 and now stand at $51,970, 11% lower after settlements or reviews.

Process safety management comes up most often in these citations: 2 items under 1910.119.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Marathon Galveston Bay Refinery averages $25,985 (2 cited inspections).

Marathon Galveston Bay Refinery: OSHA citation items per year, 2017 to 2022
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Marathon Galveston Bay Refinery and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345960975 OPENED MAY 16, 2022Closed

Complaint · Partial · Health · 1,618 employees at the site · Closed Jul 27, 2022

2401 5th Avenue South, Texas City, TX 77590 · Petroleum Refineries · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345299531 OPENED MAY 10, 2021Closed

Complaint · Partial · Safety · 25 employees at the site · Closed Jan 24, 2022

2401 5th Avenue South, Texas City, TX 77590 · Petroleum Refineries · OSHA's record · Phone and website on Google Maps

Incident on May 4, 2021: Two employees sustain burns when struck by acid after turnar

At 3:15 p.m. on May 4, 2021, two employees working as plant operators for a petroleum refinery were helping start-up an alkylation unit after a turnaround. A 3/4" bull plug was not reinstalled properly after the line was purged. The bull plug blew out of a 2-inch line releasing a hydrofluoric (HF) acid vapor cloud. This resulted in a site and community shelter in place. Both employees were struck by HF acid and hospitalized. The employees were trapped without water or proper egress causing one to have to travel through the vapor cloud and up the tower to get breathing air. The other employee had to jump off an approximate 20-foot platform to escape (captured by camera footage). The deluge system release had a delay that exceeded 30 seconds before activation after the acid cloud was detected. This event sent these employees to the emergency room due to direct concentrated exposure to the acid resulting in extensive tissue damage to the face, eyes and lungs. Employee #1 was hospitalized to treat burns to his eyes, chest, face and respiratory tract. Employee #2 was hospitalized to treat burns to his eyes, abdomen, face and respiratory tract.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.119(f)(1)(i)(g) · Process safety management
Serious$13,653$13,000Oct 4, 2021Final
Citation 1, item 3
29 CFR 1910.119(l)(1) · Process safety management
Other-than-serious$13,653$13,000Oct 4, 2021Final
Citation 1, item 4
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Other-than-serious$13,653$13,000Oct 4, 2021Final
Citation 1, item 5
29 CFR 1910.147(f)(4) · Lockout/tagout
Serious$7,802$5,500Oct 4, 2021Final

Inspection 342093838 OPENED FEB 9, 2017Closed

Complaint · Complete · Health · 1,904 employees at the site · Closed Oct 3, 2017

2401 5th Avenue South, Texas City, TX 77590 · Petrochemical Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1000(b)(2) · Air contaminants
Other-than-serious$9,959$7,470Jul 14, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.1000(b)(2)

(2) Acceptable ceiling concentrations. An employee's exposure to a substance listed in Table Z-2 shall not exceed at any time during an 8-hour shift the acceptable ceiling concentration limit given for the substance in the table, except for a time period, and up to a concentration not exceeding the maximum duration and concentration allowed in the column under “acceptable maximum peak above the acceptable ceiling concentration for an 8-hour shift.”

29 CFR 1910.119 · Process safety management

29 CFR 1910.119(f)(1)(i)(g)

(G) Startup following a turnaround, or after an emergency shutdown.

29 CFR 1910.119(l)(1)

(l) Management of change. (1) The employer shall establish and implement written procedures to manage changes (except for “replacements in kind”) to process chemicals, technology, equipment, and procedures; and, changes to facilities that affect a covered process.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.147 · Lockout/tagout

Other petroleum refineries employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.